Problem, no heat

\015 I have a 2006 tradwind model 40E with a colman-Mach ac with electric heat and all i get is cold air. I can't seem to find where the fuse is at so i can check if it is blown or where the heater element is located, PLEASE HELP IF YOU CAN. THANKS SO MUCH FOR ANY HELP YOU MIGHT BE ABLE TO SHARE WITH ME\015

Answers :

The fuse is a 110 volt breaker in your service panel. If your heat comes from the heat strip it is inside of the ac in front of the evaporator. If it is a heat pump thats the the compressor. To create heat the compressor runs in reverse. There is a directional relay operated by the circuit board and thermostat to tell the ac what you are calling for, heat or ac. The heat strip is connected to the circuit board and is also operated on 110 volts. You have one of three problems. Breaker tripped, bad heat strip, bad circuit board. Possibilities, find the heat strip cable and unplug and plug it back in a few times,maybe lost connection. That happens at times because of the warm and cold elimates. The heat strip can be tested by takeing it out and bench testing it with 110 power. circuit board can be checked by use of a volt meter, turn the ac to heat and check the pins where the heat strip plugs in. To chech the heat pump you must go up top, remove ac cover and with an amp clamp find the wires going to the compressor and put the amp clamp on one wire only. Amps should be no more than 7 amps. If it is the compressor is shot. If there is no reading then the compressor is not running. Now you may have a bad capacitor which is up top under a sheet metal cover. They also can be tested with a VOM. You will find 2 or 3 capacitors depending on model. Run and start. Capacitors typically are charged with 370 to 600 Volts. They will knock off the top of your camper. BE AWARE OF THE FACT YOU ARE DEALING WITH 110 VOLTS. IF YOU ARE NOT FAMILIAR OR COMFORTABLE GET SOME QUALIFIED HELP. GOOD LUCK

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Boiler: Vokera Option age: 10-12 years old (guess) Symptoms: when the central heating system engages the heat exchanger makes kettling/banging noises which continues until the systems switches itself off. Then re-engages problems start again, then off, then on and so on... Funnily enough the noises are most apparent at the hot water outlet. The problems only occur when central heating is on. With the system switched to hot water only = no problems. Tried the usual noise reducing additives thi


... Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

Siemens Rwb2e. I have a problem with the heating function, It heats the water no problem but have put the heating on it lights up on the display but not igniting the boiler or heating the central heating.


... Air Conditioners

I have a Goodman PC-060-1B All-in-one unit on a Double Wide home that I have one problem with and one question about; the problem is that the heating side is not working properly. I found the lower heating element to have a corroded connector, which could not be replaced, so I bought a new one and installed it along with five of the related control sensors around it. Now, if I turn the thermostat to heat, I can see the heating coils glow bright orange for about 1 minute and then the whole thi


... Air Conditioners

Hi! I have a problem with an oil heating system! When I turn it on, it heat for 5 mins then stops. I have changed out the circulation pump as I thought that this was the problem. The pipes in the boiler are warm. The heat doesn't go to the radiators around the house. I Found that only 1 radiator heats upstairs. There is water in the radiators and none are air locked as i have tried them all.


You may have many probs... 1 a poir boiler combustion. (not boiling the water) or just warming it up so it's not hot...that would mean your temperature sensor is broken or you have probs with the actual combustion process.. This could be an unsafe s ... Air Conditioners

Heating Problem Hi , My split (2 Piece) aircon is not producing Heat, but its' working on cooling. I put it in heat mode and 30 Degrees still not working for heat. What might be the problem? Please help me in regards to this. -CHAD


Put it in heat mode and check the pipes to outdoor unit,if the pipes are white from ice then the problem is to outdoor unit and is the coil of 4valve.its like a cube with 2 cables,change it. ... Samsung AS18A6RB Air Conditioner

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

I have a problem with my central heat / air unit. As it is getting cold now, I am using the heat. My problem is that I must turn the thermostat to the on position to get the unit to come on. In the auto mode, nothing happens. I can get very cold but not ever kick on until I move the switch to the on position. In the on position it works fine. Thinking that my problem was with the wall thermostat, I replaced that. I do not remember having this problem with the A/C. What should I look for to fix t


Look on your thermostat one switch (for the fan) will say off/on/auto. The other switch (for operation mode) will say off/ac/heat. The switches should be set at fan auto and mode heat. Some have an auto for the heat/ac if that is the case your thermo ... Air Conditioners

I HAVE AMANA A/C.MODEL PTC135A25AC WE HAVE PROBLEMS WHEN INSTALL NEW BOARDS THE NEW BOARDS HAVE ONE BUTTOM ON THE CENTER AND HEAT,COOL,OFF ON THE OTHER SIDE THE PROBLEM WITH THIS BOARDS WHEN PUSH FOR COOL THE COMPRESSOR WORK ONLY FIVE MINUTES AND CUT OFF AND NOT WORK MORE. IF WE NEED MORE COOL WE NEED PUSH HEAT,OFF AND COOL FOR COMPPRESSOR START TO WORK I HAVE THIS PROBLEMS ON ALL NEW CIRCUIT BOARDS ON ALL PROPERY WE HAVE 3 HOTELS WHIT THIS PROBLEMS


When you change the board on an Amana youmusty program the board. You should have gotten a sheet that shows you how to do this. I sell Amana PTAC units and all boards have to be programed for heat pump or electric heat.Russ ... Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan


The LG>LW5200ER AC is not listed as a heat providing unit. Click on link and this will give you the spec's\015\012\015\012 \015\012\015\012 ... LG LW5200ER Air Conditioner

A miswire need schematic or some direction for adding central air to a heat only intertherm electric air handler. See the problem is when a cool call is called there isnt a problem b ut when a call for heat the blower smokes. Its clearly a miswire but scmatic set up for heat only.


The blower is smoking because you have it hooked up to the same wires you've hooked the electric coil to.  That coil runs on 240 volts.  Those wires are typically red and black.  The motor runs on 120.  One of the wires should be ... Intertherm P3RA-048K Air Conditioner

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

I have a 6 year old Carrier Performance 38yza. Having a problem with heat. First no heat at all heat pump or AUX. Found AUX heat strip were grounded out and have now been replaced. Second no heat pump, Compressor comes on for only 1 to 2 minutes then shuts down. Service call yesterday Tech says no signal from Carrier Programable T-Stat, jumper heat pump, low freon adds. Says T-stat bad, but puts back together. Heat pump works blowing 90 plus degree from vent works great all afternoon and into ni


This sounds like you have a freon leak. Most units never lose freon. So that is one problem that needs to be addressed. Here is some more solutions for you: Other things that will cause or aggravate\015\012ice are clogged filters, bad fan moto ... Air Conditioners

I have an electric furnace and heat pump that will at times blow only cold air during the heating season. I have checked the filter and don't believe that to be a problem. I usually have the temperature set to 74 degrees. When the outdoor temp. is extremely cold the axillary heat indicator will be on and still no heat. I can turn the heat pump off by switching to emergency heat and will get some heat from that but not as warm as I think it should be and even that will at times only blow cool


You are losing operation to your heat strips.\015\012\015\012In heat pumps, there is a secondary heat source. Usually electric heat strips. (Sometimes a gas furnace, this is known as a "dual fuel" system)\015\012\015\012The he ... Carrier Air Conditioners

I have a Goodman Manufacture furnace, model #GMPN120-5. The furnace keep clicking on /off while asking for heat. I even turned the fan to the on position (instead of auto) and the problem continues. Heating and cooling company was called and they were not sure on the problem. I beleive that a resistor or capasitor is going bad but not sure. Please help!


Can you tell me if the burners are lighting at all? I need a little more information about the cycle. If the burners are lighting and then going off immediately you need to clean the flame sensor. A small rod on the opposite end of the burners fro ... Goodman Air Conditioners

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

We have central heat an air , the heat is up in the attic and the air is outside, our problem is that the air is blowing in the house but th unit outside doesn't come on , what could be the problem. Thanks


Check your breaker or fuses. for the outside unit. It may be getting the "Signal" to come on but there is no power. Start there and let me know. ... Air Conditioners

Hydronic Electric Baseboard Heater - PLF2004D - 90 in 240 Volts / 2000 Watts / 8.3 Apps Yes, using 240 volts Just purchased hydronic heater (Marley/Fahrenheit). Everything is good, except 1 major problem......it 'pops' The heat keeps 'popping' on and off every few seconds. Seems likes it 'pops' when obtaining heat and then stops 'popping' once at temperature. This is the 2nd time after replacing formal, thinking it was a one time problem. This is in my bedroom and is flat on the fl


Hi!!\015\012\015\012Make sure there is 240v present, there are some safety devices installed that prevent unit form working if there is a problem. In this case, I believe being on the floor and not properly installed is causing the the heater ... Air Conditioners

Won't ignite!!! My Rheem Quiet comfort 80 is only three years old and has started to have intermittent problems heating my home. There is a clicking sound, but the burners don't ignite. On other days it will work fine. I have had the gas manifold replaced, as the initial contractor bent them on installation. He said this was the problem, but I am still without heat. Help?


If the igniter is not sparking on the pilot assy the pilot will not ignite all the time. You or anyone needs to see if the spark is hitting the pilot assy. be careful not to get shocked. My best recomendation would be call a professional to check uni ... Air Conditioners

Hello all I am about at my wits end....We had a 2 ton 14 seer Ruud heat pump installed at the end of last year. The biggest problem I am having is in heat mode when it goes into defrost it makes a loud almost helicoper sound for about 20-60 seconds, wakes you up that's for sure. When I have had the company that installed it come out I can never get it to do it for them and I even tried recording it. We have had a multitude of problems I believe mostly stemming from the company that installed it.


It is most likely due to a scroll compressor. these are very noisy and hard to get used to. if it does not have a compressor jacket it would be worth installing. a hvac company would have to get it for you and it put it on. labor should be minimal si ... Air Conditioners

I have a GE ptac zoneline 4000 that wont heat on resistance but will on heat pump. It will heat when the unit has been off and the temp is below 40 f. after it has been on for 5 minutes the heat goes off but the heat pump keeps going. Checked all sensors and they all read about the same 6 k. If i put ice on the room air sensor the resistance heat comes on so I changed the sensor but, the same problem continues. This unit was made about 1994. Help Paul


... GE Zoneline AZ25E12D3B Air Conditioner

No heat I have problem with a carrier heat pump / AC the fan inside work and the air is circulating but no heat is coming out, only heat with the emergency heat come on, also the fan outside works, I change the thermostat by noting change.


Your compressor sounds like isn't working? And the problem is if we are lucky you just lost the capacitor. turn off the breaker to the ac/heat pump unit. Open the electrical panel on condenser locate the capacitor if it is swelled up like puffed u ... Carrier 38BRC048 Air Conditioner

We have a heil heat & air package unit with no heat pump and cannot get the thermostat to turn the heat off and on. We have replaced the thermostat twice and the sequencer twice and a relay once. You can bypass the thermostat and the fan and heat will come on but it won't go off by itself. We have not be able to find a schematic for this unit showing the heating side of the wiring. What can we do or what is the problem?


... Air Conditioners

I have an NewAir 12000H Portable Air conditioner with a heat pump. The problem is that the heat pump no longer seams to be working. The desired temperature is 79 degrees. the unit never gets above 75 degree. when it actually gets that high it because my heat from the house has turned on. once the heat goes off then the unit goes down to 72 degrees and stays there until my heat comes back on. whats wrong with the unit? is there anything that i can do?


It sounds like the actual control module, the "brain", of this heater / air conditioner has failed and can't sense when to kick on the heat any longer. Have you tried just unplugging the unit for a good 5 minutes minimum and seeing if it will help " ... NewAir Air Conditioners