I have Carrier 58 MVP 120 (Heat pump/gas) variable drive blower motor that ramps up then down, when t-stat is not calling for heat. When ramping up it never fully reached max rpm before ramping back down, and continues to cycle like this until I power down unit-wait-then power back up. It seem to cure it tempararly. Any idea's?


Answers :

The most likely cuase is bad connection at the board and or motor. Just pull them off and reconnect them and wiggle em.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have Carrier 58 MVP 120 (Heat pump/gas) variable drive blower motor that ramps up then down, when t-stat is not calling for heat. When ramping up it never fully reached max rpm before ramping back down, and continues to cycle like this until I power down unit-wait-then power back up. It seem to cure it tempararly. Any idea's?


The most likely cuase is bad connection at the board and or motor. Just pull them off and reconnect them and wiggle em. ... Air Conditioners

My LG LAN125 mini split heat pump occasionally shuts down in cooling mode while displaying the code CA. The LG tech tells me there is no such code. When this happens, I have to cycle power off and back on to the unit. Simply turning it off with the remote does not work. Any ideas?


Wash out your outside coil and monitor the outside fan. sounds like a lockout due to dirty condenser or intermittent motor operation. Could mean condencer air problem. ... LG LS-L1210CL Mini Split Air Conditioner

I found the Bryant furnace 395cav048090 calling for heat but not operational. I shut off power to the unit and switched power back on and the unit started its ignition sequence. With power on the blower starts as a result of thermostat calling for heat from the unit and after a minute goes on to second phase of ignition with exhaust blower motor initiated. During this phase gas is being brought to the burner that you can smell however burner does not ignite gas. Unit continued with this opera


If you do not see a bright light before the gas releases, your ignitor is probably out. If you disconnect, you should measure ohms from the two ignitor leads. If you do not measure any, it is open and will not work. You will usually see a mark of whi ... Bryant Air Conditioners

Heil heat pump makes a knocking noise (see video) switched Hunter programmable thermostat from auto (heat or AC as needed) to heat. Knocking stopped but unit runs aprox 10 mins stops running for around 5 seconds and then starts right back up for another 10 or so minutes and continues this cycle.


... Air Conditioners

Hello I have a TH232 programmable thermostat that manages my underfloor heating. Recently, it started randomly resetting itself whenever it calls for heat, i.e. when there's a light click. It then goes through a cycle of displaying everything on the LCD screen, then a 17, a 13 and then back to where it was. This also happens whenever I press ANY button on the faceplate. I am trying to contact Honeywell too, but they only seem to be based in Canada or France. Any ideas? Thanks DIY Don


Hi, The problem is caused by a weak power supply from the module behind the 'stat. When it calls for heat, and it tries to operate it's relay, there is not enough power to do it, so the voltage drops and causes the 'stat to cut out. Then the volta ... Air Conditioners

I turn the thermostat down at night. When I get up in the morning I turn it back up. The heat kicks on for a minute or two then the unit starts blowing colder air. If I turn the thermostat to the OFF position, wait until I hear all blowers stop, then turn it back to the ON position, it will start blowing HOT air again. Some times I have to perform this cycle 3 times to get it to keep blowing hot air. Any ideas as to what is shutting the furnace off? Thanks, Wayne


Theremostat switch problem. Replace it. ... Air Conditioners

Our heating timeswitch Sunvic select 107XL has suddenly stopped working; not red lights on any setting; so no heat. But it has power, and let's me change the settings. I've tried re-set and gone back to 2 PU...and started again, but still no joy. It did happen once before and then magically re-started some hours later; but no idea what's going on/. Can you suggest? thanks


Check out power plug and the power cable. ... Air Conditioners

My Carrier gas furnace (ser. 1903A41848) located in the attic, is five years old and suddenly won't light. IT cycles the fan when I cycle the power to the unit and seemingly attempts to ignite through 3 auto-attempts, (I can smell the gas), yet no continuous operation with heat occurs afterwards. Two lights exist on the exhaust vent both begin green yet one turns red after the ignition attempt. Please let me know your thoughts. -Doug


The igniters bad or if unit ignites the flame sensor is bad try this first ... Air Conditioners

When call for heat on model # WGPH-10eamer serial number DF5D302f419801914 the furance goes throught the cycles, the burner comes on and cuts off after 8 seconds. The flame censor was changed and the power was shut down for 30 minutes. It was then turned back on and the furance worked for a while and then repeated the problem. On the control board-there are 3 lights. 2 greens and sometimes the yellow one. Thats when the yellow is working right. The yellow one does not come on that much.


It could be the control board, But before I would replace the board I would check to see if the flame sensor is not touching the burner and shorting it out. Also check the flue make sure it is open. This has a combustion blower on it and a proving pr ... Weather King Air Conditioners

No heat, no flame, the furnace is going through its cycle, but the blower wont come on or flame.... the red led light on the cicuit board is flashing 4 times... the code for this says its an ignition fault..and to check the ground connection....followed the connection back to the armoured cable where the power is coming in and reconnected and checked all ground connections they are fine....the furnace is a g6rc frigidaire...what can i do..???


Is the pilot light on if not try relighting it. ... Frigidaire Air Conditioners

Furnace starting Lennox furnace model G6OUHV(X) series. Furnace would not start heating cycle unless I ran thermostrat temmp. setting up and down. Most times it would than start heat cycle. If not I would shut main power switch on furnace, wait a few seconds and then the furnace would start the heating cycle. I suspected the thermostat so beofre purchasing a new one I installed the old from my privious Lexxon. It now seems worse than ever. I either move the set points up and down (sometimes it w


Hint number 1, get HVAC license. One mistake or misunderstanding and you could blow your house up. ... Air Conditioners

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire t ... GE Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

I just moved into a new place and it has the RTH230B thermostat installed. I turned on the furnace, set the thermostat to "Heat" then the fan to "Auto" and used the up and down arrows to set the temp to 72 degrees. The temperature seemed fine for the first hour or so. However, the heat and fan stays on full power and continued to heat at full power well into 80 degrees on the thermostat screen. I could only shut it off by turning off the actual furnace switch. I first tried reducing the temper


From what you learned from your neighbor, I would say no. Certainly, sounds like a manufacturing defect to me. ... Air Conditioners

Had a power outage a while ago for 24hrs, so I went around and turned everything off and once the power came back on I went and turn the heating back on at the mains switch. Now it is coming up with "hailing master networker!", it's a Brivis unit HE20E. Have tried turning mail off and leaving 5 mins. Message is still there.


Pull the controller off the wall, press 3+5 buttons down, then replace on wall while still pushing buttons in.... a group of 5-6 bars will appear, then when it says type in address -turn dial to 1. this will re set it. ... Air Conditioners

Shutting off I have the AC on cool at 77F, one fan selected, and energy saver on. After it runs for a few hours, it shuts off but the display is still lit with the above settings. When I press the energy saver to turn it off, the AC comes back on. Alternatively, if I power the AC off (display is off) and power it back on, it runs normally (but don't know whether it shuts down again shortly). Any ideas? Should I reset it?


I would try the same solution as the E1 error code, Not sure if it will work, but it seems to be the same issue1. Power down the air conditioner using the "power" button on the front\015\012panel.\015\0122. Unplug the ai ... Sharp AF-S120FX Air Conditioner

Thremostat reaches and exceeds temperature setting but frunace continues to run, remove trermostat from wall and furnace continues to run. Not just fan- entire system, I have removed both panels from the furnaced itself and as soon as power is supplied the furnace immediately lights (gas) and begins to heat house. Current inside temperature is 77; set to heat to 70.


... Air Conditioners

Trying to determine whether I have a bad Ign/Lockout or inducer relay board on Mod 58SXA080-GG. If I shut off heat at t-stat or unplug ign mod. for 10 min. It will usually intiate a heat cycle but I only get inducer blower for 10 sec, no pilot, no spark. Then shuts down. Will not auto retry (normal?), I have to remove power. I do have 24V going to relay board when cycle starts but drops out when motor stops (I assume this is the ign module lock out). I checked the air switch by ohming out while


The inducer blower will put a vacuum on your pressure switch which in turn will tell the board to apply power to the ignitor. If you have a vent blockage, dirty air filter, plugged condensate line or any blockage of either vent or air intake, the fur ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Honeywell thermostat; Lennox elite series furnace thermostat reaches and exceeds temperature setting but frunace continues to run, remove trermostat from wall and furnace continues to run. Not just fan- entire system, I have removed both panels from the furnaced itself and as soon as power is supplied the furnace immediately lights (gas) and begins to heat house. Current inside temperature is 77; set to heat to 70.


When the furnace exceeds the temperature set by the thermostat, this could be indicative of several issues. The thermostat mounted crooked. When a thermostat isn't level on the wall, it can affect the automatic on/off function. To fix this pro ... Air Conditioners

My 8 yr old Amana heat pump, model RHE48A2D with Honeywell progammable thermostat in heat mode has the blower running constantly. When there is a 6 to 8 degree differnce between room temp and thermostat setting compressor runs as it should, the closer it gets to thermostat setting, it will run about 30 seconds, blower continues to run until getting just cool air, about 5 minutes, compressor kicks back on for 30 sec., continues to do this, thermostat shows it has reached set temperature,


Hi, It sounds to me like what you are describing is, that when it is 6 to 8 or so degree difference then the stat says, unit operates as it is supposed to but then before it satisfies the t-stat, it shuts the compressor down long enough to start cool ... Air Conditioners

Installed new LG 18000 btu mini split heat pump, started it in heating mode, the unit first appears to run fine but continues to cycle in and off without reaching temp. have already changed indoor board and thermister per LG tech support request, but unit still cycles without satisfing.


A heat pump is a finely tuned machine that can be very efficient yet very frustrating at times. I could give you better advice if I were looking at the unit but hear are some things that may help. The unit has a defrost mode that cycles every 30,60,o ... Air Conditioners

We have recently bought a house with Vulcan ducted gas heating (no pilot light). When the system comes on it produces plenty of heat so I don't think there is anything wrong with the unit itself. Frequently, however, it reaches the set temperature, turns off, and then will not come back on even if we press the on/off button. The only way we can get it back on is to cut power to the house and then press the on button. That would suggest that there may be some kind of program set, but since


By the things you said here it seams that is nothing wrong with the device itself but it has something to do with the thermostat ...The thermostat is the part that it supposed to shut it down when the temperature gets to the set value....and also it ... Air Conditioners

I have an intertherm electric furnace FEH-A020, with multispeed blower installed when A/C added. My problem is blower operation. at the end of the cooling season with fan set to auto operation the fan ran continuously. Now that I've turned the unit back on for heat the blower will only function with the switch in the on position (continuous operation), in auto mode the heating elements come on with the signal from the thermostat (Honeywell CT3400), but the fan does not. I checked the fan relay p


The model of T-stat you gave comes up as a discontinued model on Honeywell's web site, but it looks to be a manual stat that type of stat would have to be wired with a summer winter switch with electric heat, allowing it to turn on the fan with a cal ... Intertherm P3RA-048K Air Conditioner

No heat My air conditioner on my unit went out via power surge back in the summer. A/C man came out and rewired the circuit board so we could have A/C but the heat would not work. He had to order in a new pc board. Since all of that happened, A/C man has gone out of business. Now no one wants to come out and fix what he messed up without charging the **** out of me. I already paid once and don't want to pay again, at least not yet. Can some one tell me how to rewire that pc board to get heat, ot


THERMOSTAT ... Intertherm P3RA-048K Air Conditioner

Our furnace went into lock out and so I cycled powere and it reset it started working again but not correctly. The inducer motor wis coming on for a few minutes then the hot ignition comes on and the gas lights. then the blower comes on then shortly after the gas cycles off and then a few minutes later it cycles back on and usually the fan alternates on with the gas. I started checking the safety switches that go to hot ignition control. (24V) Once everything was running the 24V would drop to ze


Boy it sounds like a high limit opening up and shutting off the gas valve. It won't shut off the blower because it wants to cool off thge furnace. Check for any restriction in the air delivery system, filter, registers. Check for blockage of the exha ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1222 seconds