Circuit board burnt (goodman hotel unit)

\015 I have 2 units (model ptc123b50ambp) where the control boards have burnt (melted the center relay (I don't have the board handy so I can't tell ya what the relay is for)) what could cause this problem?\015

Answers :

Make sure everything is wired up properly. make sure that your 24 volts is correct(low voltage and your 120 volt transformer.) make sure the breaker is the right rating /amp. check nameplate so you will know proper information

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Circuit board burnt (goodman hotel unit)


Make sure everything is wired up properly. make sure that your 24 volts is correct(low voltage and your 120 volt transformer.) make sure the breaker is the right rating /amp. check nameplate so you will know proper information ... Air Conditioners

Hi we have a burnt out circuit board in the cooline a/c unit under the house, is there a place that ells spares to the public? we are in brisbane queensland


Cooline units are imported to your country from Kuwait. I doubt they are making them there - but I don't know who does make them.Try calling: \015\012 Tri-Tech Air Conditioning Services ... GE APH10AA Air Conditioner

Hello, do the relays on a goodman ac unit circuit board snap in or are they soldered?


THEY ARE SOLDERED ON AND SNAPPED ON THROUGH A CONNECTOR ALREADY MOUNTED ON THE BOARD AND THEN SOME OF THESE CONNECTORS HAVE WIRES LEADING TO AN \015\012EXTERNAL RELAY. NOT ALL RELAYS ARE ON THE BOARD.. THE BOARD ALSO CONTAINS RESISTOR ... Goodman CLQ36AR49 Air Conditioner

I have a goodman heating and air unit .... a problem exits ... ES swith open .... where can i find the ES switch on the circuit board?


... Goodman Air Conditioners

Our evaporative cooler fan does not start when we turn on our unit - it will run if I get up on the roof and start the fan blades spinning... We could smell a burnt motor smell when the problem started. Is it just a fuse? or is it a new fan motor? We just spent $600 to replace the circuit board and the solenoid - hoping to avoid another big bill...


Hi,It is just the circuit problem.Not fuse not motor.From the circuit board to the fan there is no start flow of current passing on to spin or to make it start.Check the flow of volts out of the board.Please do rate the solut ... Air Conditioners

Have 2 dometic duo-therm 13.5 penguin model 620015-307,front air would not start no lights electronic control unit,swapped control units with rear which was working fine,still did not work,swapped circuit boards from ac units neither unit works,returned original circuit board to rear unit now that doesn"t work either...help


Hi,It would seem as though something in the front unit is killing the circuit boards....The front circuit board was bad so the control still did not work in the front...then you swapped the circuit board from the back and killed it in the ... Dometic Air Conditioners

I have a AOBR12JGC outdoor unit. I start the unit everything goes normal, but after a few minutes the compresor tries to come on , but it cant. No error messages nothing. The A/C has ground. the unit is 6 months old. I have change indoor unit circuit board, outdoor circuit board and the compressor is OK. Any idea?


... Air Conditioners

Carrier 36K wall unit. Lost remote control. Bought new remote from local Carrier dealer. New remote does not control unit. Technician replaced circuit board in unit, but remote still does not control unit. What to do??? Buy circuit board and remote together that are known to work with each other??? Help, thanks!! Evans Bell


Buy circuit board and remote together that are known to work with each other (sic) I think you have answered your own question.. very sagacious.\015\012\015\012To my mind that;s really all you can do. I am surpri ... Carrier Air Conditioners

Circuit board on AC unit at home was replaced, turned on unit and new circuit board burned also burned spots at the same locations as older board? What could be the problems?


You have something in that circuit that's pulling high amps or shorted. You need to determine what is in that circuit fan, compressor, contactor, wiring, etc and fix it first.\015\012Until you fix that you will keep burning up boards. ... Air Conditioners

I was expecting to find this relay. It's not there. My unit has a rather complicated looking circuit board. The circuit board seems to have been made by Emerson Climate Technology. On the top edge of the circuit board is printed "Climate Talk" and the number "4672H". There is also a Bar Code sticker affixed to the circuit board that bears the number 11014630400034. Where do I connect the thermostat wires (red & white)?


This board needs a 24 volt supply run from the furnace to power up the communicating board\015\012check your wiring diagram on the inside of the panel this will help you ... Amana Air Conditioners

I got a Carrier Flowtronic with two recips and EXV's. Unit goes out on compressor failure. Ran test mode and EXV's operate normally. Pressures look good.(R-22-260 head, 65- suction) The unit only has a high pressure cut-out and a suction thermistor, which had been recently changed. First circuit A failed and would not reset. Then circuit B failed. Now the unit is running on circuit B. Thermistors ohm out good and expansion valves are doing O.K. as well. Installed a new MBB board and configured i


Theres a major malfunction with the unit,, trying diff things can cost you alot of money for some thing like that i would contact the makers for tech advice as trying diff, things is costing you alot of time and the cost with be greater in the end th ... Air Conditioners

Have AMCORAIRE mini-split purchased in 11/08 and installed in new guest cottage on 7/17/09 by local AC tech. in Cocoa, FL. Unit worked fine for approx. 7 months then stopped working with error code F!. Called AC Tech who installed unit and he called Pridiom tech support and spoke to Alan while trouble shooting unit. They determined that trouble was in circuit boards and suggested replacing boards, which were back ordered or buy new outside unit. The unit is a 12,000btu mini- split with heat


Try this link. They will be able to help you with your concerns.\015\012\015\012\015\012The FixYa Team ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

Hello , this is Bobby and I have a Coleman Mach rooftop air conditioning unit Model # 8335B8964 when I turn on the unit ,it throws the circuit breaker . I have replaced the starting capacitor and the running capacitor for the compressor, the fan runs ok.Is there a circuit board for this particular unit?


Here's a link to a service manual, with step by step tests to determine whats wrong. I'm thinking compressor shot, but this should confirm, and or help you determine for yourself. Be careful with those capacitors eh !! Read warning in service manual. ... Coleman Mach 15 Air Conditioner

My goodman central air unit quit working after a storm. The circuit breaker is not blown. The furnace fan kicks on when ac is turned on at the thermostat but unit outside does not operate. Is there an internal fuse or capacitor on outside unit. Thank you very much, Bryan Model CKL36-IF Goodman


1 posible cause.the thermostat supplies 24 volts to the outside unit to control the contactor if you hear a ligth huming on the outside unit this is the being activated. if this is the case then\015\012\015\012 check to see if any ants are in ... Goodman Air Conditioners

My father has an older model two and a half ton goodman gas package unit. it has had two boards put in it, the problem is that the unit will go through a heat cycle and the combustion motor and the circulating fans will not cut off. The loop from the board through the limits is fine. The new boards did not fix it, all components check out.


The fan induction motor produces a vacuum, check of orofice on motor is plugged by pulling hose off switch end and putting in mouth while running and sucking, this will make a whining sound immediately if no restriction. the fans are controlled throu ... Air Conditioners

I have a 2005 winnebago adventurer.I have a coleman mack basement unit the fan will come on and my heat will but my a/c will not come on the circuit board the circuit board has a green light that steady blinks green.


... Air Conditioners

My heat pump will not come on in HEAT or A/C. I thought I might have a simple defrost control board problem, but still no go after replacing the board and the defrost relay. I checked the pressure switch and it is not tripped. I've checked all the circuit breakers and they, too, are all set. I've checked the outside unit using the "test" switch inside on the start relay and the unit will come on, but won't stay running on it's own. When I select HEAT, I wait the necessary five minutes for the un


Hi; Need more info. How old is the equipment,look on the outside unit data plate it will give the built date usually in the top right corner. Also heat pumps can run with a faulty defrost board. I would check for control voltage at the secondary side ... Ruud UBHC Air Conditioner

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

HI, I had a gas furnace (GOODMAN GMP125-4).When i turn heat on from thermostat, the burner is not light up, the induction motor is not running. I took off the panel and I also found that the status light (red light)on Circuit board is NOT on also.Is this a circuit board problem or thermostat problem?


... Air Conditioners

Furnace shuts down before heat temp meets thermostat. Furnace unit starts frequently. Service installed new limit switch and a new circuit board but furnace unit continues to malfunction. Same problems after service as before limit switch and new circuit problem installed.


Has any one checked your thermostat. as soon as the furnace shuts down then turn up the stat and see if it starts right up. i would think the stat function should have been checked also. ... Air Conditioners

The f1 fuse on the circuit board keeps blowing out on a pth073b35aj amana unit. i've replaced the circuit board and thermostat to no avail. thanks keith


... Amana PTH073B25AJ Heat Pump,7000BTU, 230V, 2.5KW PTAC Air Conditioner

I have an Amcoraire model AOS091HX that also displays an F1 error code. Fuses were blown on the outside unit. I read about the fix by replacing the capacitors in the middle of the circuit board. I contacted Pridium and was told the circuit boards from China have been on order for six months, so I have nothing to lose by replacing a capacitor or two. Any other advise would be greatly appreciated.


... Air Conditioners

Hi,our bonaire evaporative cooling unit blew a mov in the circuit board which i had fixed,i had a mate install the box and went inside and started the unit up and could hear the motor sound like it was running but could not feel the air flowthen it shut off and the fuse blew in the curcuit board,could it be the actual fan motor that has had its day? cheers Darren


... Air Conditioners

The dometic roof ac humms when rv is on 110 ac unit was under warranty dometic sent a complete control board I changed control and stil have problem just like before. Dometic said one of the relays was welded or burnt out or closed which is causing the problem. unit works just doesnt stop humming when turned off .Not likely two bad control boards?? Mod.9597.....


Not likely but possible. if they already had one bad board what's to say their production methods have changed since they made your last bad board. I have just had 6 bad compressors from this chinese company danfoss in one month! for only 2 freezers ... Dometic Rooftop RV Air Conditioner

Mr Slim - MSZ-A09NA quits - error light blinks every second after every rain. The circuit board, I understand 2 different ones, replaced more than once. Sometimes after a period, unit will operate normally - as if something dried out. Circuit breaker tripped twice but unit stopped several times. Any ideas? (I have 3 of these, only one has the problem)


... Mitsubishi Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0778 seconds