Having problems with your Air Conditioners ?

Cools for a limited time only before unit must be reset

\015 The unit I bought was set up just a week ago and after my a/c guy fixed all the error messages that were coming up the unit still doesn't work properly.The A/C will seem to be operating normally until anywhere between 4-6 hours later the unit while still sensing that it needs to cool the room only blows air at the same temp. as the room.This is easily fixed by turning the unit on and then off again but this certainly won't work for me as I'm using the unit to cool a server room and as such is left unattended for long periods of time...\015

Answers :

If the unit was set up a week ago the technician should warranty his work and come back and take care of the problem for you, not knowing what was set up and how, it's hard to say if it's a problem with the unit or the control (t'stat or programming if it's a programmable t'stat).
If this unit was new one and setting was done accurately,It sem that the ac is tripping off due to several factors in case of tripping off the compressor there is a hi pressure that building up on hi side that could not expand normally on expansion valve,there's clogging of some impurities or substance such as air in the system,this will develop a high current to your compressor exceeding to the rated current of unit,resulting to trip off the ac.You can check this on taking the operating current while the unit while is running using clamp ammeter the current will register and compared this to rated current that specified in the compressor manual or the compressor casing it was tag there.Or check again the set up sequence at the remote control the variation of thermostat setting.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Cools for a limited time only before unit must be reset


If the unit was set up a week ago the technician should warranty his work and come back and take care of the problem for you, not knowing what was set up and how, it's hard to say if it's a problem with the unit or the control (t'stat or programming ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

Indoor Sanyo ductless split Model # KHS 2432 serial # 0012832, Works fan on and off functions and speeds. As soon as you set the remote to heating or cooling the unit beeps 5 times quickly and then the unit no longer responds to remote control. The blower will then run for 1 minute and then the the unit no longer will work. Power must be reset for blower operations to function again. Out door unit, has enough charge, Ambient temp 39 M#CH2432 S#0012424


... Sanyo Air Conditioners

No cooling I received a call from my tenant that they have no ac. When i get my inspection of the unit to find an extremely durty air filter, which i replaced. Also i cleaned the a coil which was also full with dust. So i figured the time it took me to to do all that cleaning that the unit had time to reset it self. Long story short i still have no cooling at all still. through the first sequence of operation every thing seems ok . dtill no cooling


"You forgot the "first rule , check to see if everythings is working! If the filter was dirty , then you skipped the second line of defense to prevent dust from going into the vents is the squirrell cage blades. Air flows thru the filter first,,,2ond ... Goodman CKL36AR36 Air Conditioner

I have 2 Frigidaire window a/c units, model# fam18eq2a1. The landlord tells me they are brand new. Both units have the same symptoms: about 30% of the time they power on and function normally. The rest of the time nothing happens when you hit the power button. After checking the appliance plug in to make sure is plugged in, I then hit the reset button, afterwhich the digital display lights up completely, beeps, and then usually goes dead, although 1 out of 15 times it will power on and cool f


... Air Conditioners

GE Air conditioner wall unit started on 7.19.10 stopping for no reason, continued stopping on 7.20.10 like 3 times (10.40 p.m. and 2 times after that) and had to reset a/c; 7.21.10 a/c stopped at 10 p.m. - reset a/c and today, 7.22.10 NO COOL AIR at all! The fan feels cooler than the A/C. What's up with that?


... GE APN08AA Portable Air Conditioner

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

I have a dometic duo therm rooftop a/c on my camper. On initial startup, the unit performs fine and cools until it reaches the setpoint of the thermostat. A few minutes later though after the thermostat calls for a restart, the unit will run for a short time and then the breaker will trip. On occassion, I can reset the breaker and get the unit to keep running. This appears to occur randomly though. I'm thinking it's one of the capacitors?


Possible capacitor, but I'd check what else may be drawing power at same time in trailer. Try running everything possible on propane rather than hydro so that there is no other, or minimal current draw besides AC, and see if that makes a difference. ... Dometic Rooftop RV Air Conditioner

Mistral mss 1.0kw unit - When switched on the indoor unit & the outdoor compressor runs normally but the air coming out of the blower is not cool even after a long time. Is there a reset button to push? Thanks.


If the indoor unit blower is running and the outdoor unit fan is turning, you will need to make sure that the compressor itself is actually running and that it is not just the outdoor fan that is turning.\015\012Get close and listen to the end ... Sanyo 24KS32A Cool Mini Split Air Conditioner

I have a RUDD AC 5 ton and the inside unit is running and blowing but the air is not cooling and the outside unit is not turning on. I checked all the breakers and tried pressing the reset button on the bottom. Is there a trick to pressing that button....nothing seems to be happening...do I need to hold it down for a certain amount of time? Thanks! It is getting hot in here....


Is the contacror pulled in? If not check the low voltage to see why it isn't, if it is, check for voltage out the other side with a meter. ... Ruud UBHC Air Conditioner

I have a friedrich ductless split m# mw24cy3f .. call for cool only fan runs inside, call for heat nothing runs, outdoor temp at the moment is 38 degrees, error code light blinks on indoor unit... operation and timer blinks simutaneously 2 times then operation blinks 5 more times. not sure what the error code means and how to reset and correct the problem.


Not able to find the error codes for the unit number you gave but, here is a number you can call to get them. sorry not more help.\015\012\015\012\015\012\015\012\015\012\015\012\015\0121-866-793-0323\015\012 ... Friedrich Air Conditioners

Breaker breaks When my Dometic roof a/c compressor comes on during a regular cycle, it sometimes pops the breaker. I replaced the breaker but think there must be some sort of timer in the unit that allows some time to go by before the compressor comes back on. If I reset the breaker and turn the unit back on immediately, it pops again. If I wait about 5 minutes it will run ok. The amps are ok. Help.


This unit may have an internal overload mounted on top of the compressor. You would have to get to the\015\012compressor to find out and it maybe faulty. That may\015\012explain why the compressor comes on later on, this\015\012over ... Dometic Rooftop RV Air Conditioner

Klimaire KSWG024 indoor unit with turn on for approx 2 minutes. It will run in fan or cool for this amount of time. Then the auto light flasher rapidly and the unit does not work until the power is reset. Problem then repeats.


... Air Conditioners

I have a Carrier 42PQV080 that is shutting itself off during cooling. The power light flashes six times green then once orange. Sometimes it will come back on by itself, but generally turning the isolating switch on and off will reset the unit for a little while, but then shuts off again. Any ideas??


... Air Conditioners

Futitsu Inverter Air-con {ASTA09LCC}- Fan operates but no refridgerated air. Remote is on 'cool', fan speed is on medium. When the unit is switched on the Operation light (red) and Timer Light (green) flash twice together, then Operation light flashes five times this reapeated after about five seconds. I am told that this can help diagnose the problem. I have reset the remote to cler any chance of the 'Timer' being set.


To cancel the timer, press timer on setting until it comes 00.00. Or remove batteries from remote and re fix after few minutes. If still problem persists, check and rectify error code of e-5 as follows: Comms Error, check your wiring, rem ... Fujitsu 24C1 Air Conditioner

For the past two days I have had to reset the main circuit breaker for the outside unit. It appears to be running fine now. I'm just wondering is this an indication of the compressor about to go bad, overuse due to the hot weather we're having or the compressor overheating and becoming temporarily "stuck" until it cools down? I haven been able to check the current draw with my amprobe yet, and the thermostat has a "time-out" feature so I don't think the problem is "short-cycling" Just fishin


Bill, first thing, make sure the outdoor coil isn't stopped up with dirt. This will cause the compressor to overheat and possibly trip the breaker. If you you can check the amp draw that would be good. Look on the data tag on the outside unit and lo ... GE Air Conditioners

Unit leak at high pressure port. repair man replaced valve charged unit.cooled for a short time then stopped cooling.another repair man found low coolant,thought evoperator leak to be the cause. injected stop leak [944 kit super seal hvacr 1 ton to 5ton]. unit cooled for short time. now does not cool. runs and sounds good but no cooling.


Sorry about your problems.The StopLeak is expensive and does not work on leaks larger than 8 ounces per year.Neither of these "technicians" confirmed the location of the leak and repaired it.When the vacuum was done on the system a ... Ruud Air Conditioners

I have a 2011 Wildwood travel trailer. I tried to use the air conditioner for the first time this weekend. When I turned the themostat to cool and 65 degrees the air unit "clicked" one time but the unit did not start. I tried various settings but nothing. When I turned the thermostat off the unit clicked one time again. This is a brand new trailer and the first time I tried the air. Any thoughts?


First thing to check is that the breaker for hydro to AC unit is in the on position. The clicking sounds like 12 VDC is OK but hydro may not be on to it. ... Dometic Rooftop RV Air Conditioner

I have a 24,500 BTU LG installed in my window. The unit works wonderful when it actually cuts on, its brand new, and is able to drain, and installed per the instructions. The unit stays on all the time, but will only cool for 5-10 minutes at a time, the rest is just the fan running with no cool air, just normal temperature air. What am i missing?


Possible bad thermostat. ... LG Heat cool Window Air Conditioner

My LG art cool units stop frequently and show a code of C8. I turn the unit on and off again and then works until the next time....This has been going on for several years now, is annoying/concerning, but each time I have a professional come to visit they tell me the same thing....that the C8 means the internal fan is blocked, but if by turning it on and off the problem is solved then the fan is not really blocked and I should not be concerned. I have two art cools and this happens on both of


... LG Art Cool LA121CNP wall/window Air Conditioner

HAVE A COLEMAN MODEL DRHSO601CB --- THE UNIT WILL RUN FINE FOR SEVERAL HOURS WITH GOOD COOLING AND THEN PERIODICALLY THE TROUBLE LIGHT WILL COME ON THE THERMOSTAT AND THE UNIT HAS SHUT DOWN. TO RESTART - YOU MOVE THE THERMOSTAT TO OFF WAIT 5 MINUTES OR SO AND PUT IT BACK ON COOL -- IT WILL RESTART ALMOST EVERY TIME AND RUN FOR SEVERAL HOURS. IN THE PAST IN THE PAST I REPLACED THE DEFROST CONTROL BOARD BUT WHEN I DID THAT THIS TIME IT STILL SHUTS DOWN - WHAT OTHER PROBLEMS ARE YOU AWARE OF ON TH


You may have a low pressure or high pressure switch tripping out the board as well. You might try cleaning both the indoor (evaporator) coil and the outdoor (condensing) coil. Be sure to turn off the power source before servicing this. ... Coleman Air Conditioners

I have a Mitsubishi MS-09D wall mounted air conditioner. The cooling function does not seem to be cooling. The fan is running but the it seems to be recirculating the air only. The defrost light is red on the wall unit. I don't recall this light ever being on before. Could a button or combination of buttons on the remote unit have been bumped somehow? Could you please tell me how to reset the remote control or wall unit to have the cooling operation to come on again? The air ducts are clean,


... Mitsubishi Air Conditioners

3.5T/10yr.old ELEC. cooling was ok until I switched over to heat. Unit failed to activate compressor until I touched the reset. once started via reset the unit worked thru initial cycle but often fails to restart without reset. called service and they enfused R-22. issue not corrected, called serviced again and high pressure side exceeded 400 when 250 normal. service recommended replacing unit believing there was a stoppage in the fluid line. Subsequently I replaced the filter in the air handle


It sounds from what you just described, that your problem was the dirty filter to start with.\015\012Then the tech added charge to the system, which i'm sure that he now has it overcharged.\015\012Try removing some of the refrigerant unti ... Ruud UBHC Air Conditioner

I have 2 heil heat punps (manufactured 1989), a 3T for the lower level and a 2.5T for the upper level. The 3T unit functions normal. The upper unit functions normal if each spring, when switching from heat to cooling, the technician adds 4 pounds of freon to cool properly. In the fall the tech must draw out 4 pounds of freon for this unit to heat properly. The outside and attic units are a matched set and the expansion value in the attic unit has been replaced. There's no leaks and several


Hi,\015\012\015\012To properly trouble shoot this there is much more information needed....\015\012\015\012The exact model numbers of the indoor and outdoor units...\015\012The line set sizes and the lentgh of the line s ... GE AJCH10ACB Built-In Room Air Cool Unit

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

Unit won't cool. Unit is set on is on cool, but warm air comes out. Is there a reset button on the unit ? Unit is 21 1/2 years old.


Some of those old Mach 3's have a manual reset pressure switch, but you will have to take the cover off to find it. Most manual resets have a red button to push to reset. The unit may be low on refrigerant or the condenser coil stopped up with dirt ... Coleman Mach III Air Conditioner