Having problems with your Air Conditioners ?

HVAC will not turn on

\015 My air conditioning unit will not turn on. The technician that came out said that the freon was only half full and he found a small leak outside. Can this be the cause of the unit not turning on at all? It wouldn't blow any air. I have had 5 service calls in the past 6 months for the upstairs and downstairs units not coming on when they should. The technicians that respond are all from the same company and are answering a call for a warranty company. They have told me they couldn't find anything wrong until this call. When the heat wouldn't come on periodically they found nothing that would cause it.\015

Answers :

If the freon pressure gets low then the low pressure cutout switch kills the low voltage to the thermostat and the unit will not run.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The circuit breaker trips every time I turn the thermostat to on. The system hasn't been on in a few months, and when I turned it on today, it wasn't pushing cold air out. I saw that the circuit breaker trips for the "HVAC" in my panel as soon as I turn the unit to on. This is A Goodman Model A 36-15


You need to start with a basic inspection in the outside unit. For the breaker to trip immediately like that indicates a dead short. With the breaker OFF look at the internal wiring between the contactor relay and the compressor. You are looking for ... Goodman CLQ36AR49 Air Conditioner

HVAC issues - A/C blows semi-cold air and Heater won't turn on


Hi! there,\015\012 there are possible cause in the circuit is the thermostat,since thermostat switch is like a switch of light,when this turn on blower and compressor turn on,if you turn on and no cold your thermostat\015\012is defect ... Air Conditioners

I have a 15 year old HVAC system that uses a Carrier Weather Maker 8000 furnace. When we returned from vacation last week, we noticed that the furnace blower motor would not turn on. The A/C compressor and condenser fan would turn on, but not the evaperator/furnace blower fan. I started a component test, but the LED just continuously blinked rapidly. The code associated with this is "Line voltage (115V) polarity reversed or twinning problem. How do I fix this?


The control board seems to be detecting reverse polarity, and my first thought is that the relay contactors are oxidized, but you could also have a bad startup capacitor, and/or control board.\015\012The only reason I say control board is becau ... Air Conditioners

Goodman AR-36-1: We had to call a HVAC person each year for Heat and AC at the begining of each season.The compressor will not come on to make the A/C work. Feeling that I was being hustled, this year I went in the attic and opened the devise in order to see if the breakers were working or turned off, by what I thought was a good relaible HVAC person. When I open the unit, I discovered a black wire hanging down with 240 volts of current not a attached to anything. Does any know if this is


There should be 2 hot wires and a ground wire coming into the air handler. 120 volts on each wire totalling 220/240 volts across the 2 hot wires.\015\012The 2 wires should go to a terminal block where the power is then distributed to the fan mo ... Air Conditioners

My indoor unit on my heat pump will not shut off. The electric heat keeps running, and the fan keeps running. It only happens when it is really cold, like 25deg or below, above that and it functions fine. The outdoor unit shuts off, but the indoor stays running. I do HVAC work, but I have never seen a problem like this. I have switched the stat out, and its just so strange. I figured the relay may be stuck, but if I turn the stat off, it turns off shortly after which tells me it may not be the c


I would venture to say your stack relay is getting stuck. either that or you have a short in your low voltage wiring somewhere that is not always making contact....or it may be making contact through another median...like ice or frost. Remember ele ... Intertherm P3RA-036K Air Conditioner

I have a new Carrier HVAC system with a fancy EDGE thermostat. When I turn the system OFF at the thermostat, and set the fan to AUTO, hours later I will find that the fan is running and it's setting on the thermostat is now ON. How can I permanently turn off the fan when the system is off?


1. Open the door.\015\0122. Press and hold the buttons underneath the heat\015\012and cool setpoints simultaneously (the two bottom\015\012buttons on the right) until the screen displays the reset\015\012reminders and 01 in the lower right corner.\01 ... Carrier 36KCARMS Air Conditioner

Hvac system My air isn't working properly. When I turn it on you can hear the unit out side come on but the air is barely blowing and isn't very cool at all. So I turned the furnace from auto to on, it is blowing now but still isn't cool. Can somebody tell me what my problem may be.


Sounds like you have frozen up. Turn your system from cool to off and your fan from auto to on. Let it run for an hour or so. If blowing seems to be normal again, you may have a duct problem, dirty coil problem, or a low on refrigerant problem. ... Intertherm P3RA-048K Air Conditioner

We have a Trane 5 Ton HVAC. When we turn on the air conditioning after it has been off in the winter there is a terrible smell. We have had people out, and they say it's just condensation. They tell us to turn it down very cold and it will go away. It eventually does, but why should we have to go through this every time? In the previous 21 years in this house with two previous systems we have never had this problem. We live in Texas and sometimes we actually need a/c in the winter. But th


Have any actually flushed the drain line to be sure they are for sure clear and open , and is the trap for the drain installed as per mfg reccomendations , sound as if some of the condinsation is remaing in the drain pan of the unit ... Whirlwind FH-778 Air Conditioner

Goodman HVAC blower fan will not turn on for AC (but it will turn on for heat). Trying to repair.


I'm not sure what turns your fan on and off but it could be a seqencer that has gone bad. If would be located in the inside unit close to the electric heat strips and the fan relay would be connected to it. The sequencer will be black and may have se ... Goodman Air Conditioners

HVAC will not turn on


If the freon pressure gets low then the low pressure cutout switch kills the low voltage to the thermostat and the unit will not run. ... Air Conditioners

My york hvac unit will not turn on thermostat says heat 2nd stage and fan is always on


... Air Conditioners

HVAC Blower will not turn off


I doubt it is something you can fix yourself--best bet is get a expert out before the issue gets worse or something that is good now gets damaged. ... Amana GMH81405DN 140,000 BTU 80% Gas Furnace, 2 Stage, Multi-Speed,

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

I have a GE ZONELINE 5100 hvac unit when unit is turned on the blower works but it will not generate heat when set on heat selection nor will it blow cold air on cold air selection it just blows air out like normal fan what could be the problem


Check the selector switch to make sure that the controls are transferring from heat to cool. Then if the control is working you would have to check power to the valve that changes the flow of refrigerant from heat to cool. This unit may be heat ... Air Conditioners

My ac unit is not working properly. It stoped working the other day and we called a HVAC out. He said it was the transformer. Replaced that and put a new stat on. Then in less than 24 hours the thing stops again. Replaced the transformer again. The unit will not work right. The fan blows on the (on) position and the heater part works but everytime we turn on AC it makes a buzzing or humming sound and does not come on. If we leave it like that it will burn out the transformer. We replaced the rel


You are going to have to eplace the contactor inside of the outdoor unit, the coil is weak ... Air Conditioners

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

My wife and I just purchased a home built in 1900. It has two separate HVAC systems, with a package unit downstairs, and a traditional compressor/furnace combo in the upper. Most of the windows are in need of replacement as they allow quite the draft. Also, the original hardwoods are not insulated underneath the house. Everything aside, my problem lies with the package unit downstairs. With the unit turned on there is very little heat coming out of the 2 or 3 vents closest to the unit, and no he


With that large of an opening I would inspect the blower and as much inside the unit as I could get to as there is no telling what might have gotten in there and is obstructing air flow. I would remove squirrel cage and blowere motor and clean thour ... Air Conditioners

My Mr Slim Model # MSH09TW suddenly is turn off in the middle of the night. Then comes back on for 5 minutes, then stop and blows nothing( with the green light on). I've had the HVAC people service the unit, tested and did a setback, replaced the batteries in the controller and the problem still exists! What needs to be done?


It sounds like the thermal overload it kicking it out. The thermal overload is to keep it from starting a fire. Something is getting hot inside the unit. ... Mitsubishi MSH09TW Air Conditioner

Hvac systems my air isnt blowing very well so i turned the furnace from auto to on it is blowing now but it still isnt cooling the house what might my problem be


1. Check and/or replace the filter in the air handler\015\012\015\0122. Make sure all vents are open and not blocked\015\012\015\0123. System may need inspection and charge ... Intertherm P3RA-048K Air Conditioner

I have had a mitsubishi split system HVAC installed in my 150m apartment. It is installed inside the apartment in a small space with one window for inflow a second window for out flow. As we test the unit, 3 problems have come to our attention. (1) When it was really cold outside last Janaury the unit itself was leaking something that turned into ice. There was a pool of about 2 inches of ice on the floor and the wall had a covering and the hoses were encased in ice. The installer maint


The problem is in your Ac's compressor .It is wasting all the cooling gases and chemicals1)the ice you are seeing is the mixture of chemical & gases when get in contact with atmospheric air it converts into ice and pls dont touch that ice a ... Mitsubishi MS-A09WA Split System Air Conditioner

The infamous 'whistling" gas valve. what would cause this?I turned the screw all the way in, and it stopped, hurrah. BUT,I noticed as soon as the burners light up, for a split second, the valve will whistle, then stop What gives? Licensed HVAC contractor


... Goodman Air Conditioners

Hi, I have a Honeywell Thermostat T8400 (non-programmable.) The screen is blank and will not come back on. I've unplugged it from the wall and turned the electricity off and on in an effort to reset it. It doesn't use batteries. The unit isn't working at all. Any suggestions or should I just call an HVAC guy? thanks, lisa


If you thermostat doesnt use batteries and it has no power, that means there is a problem with the air conditioing system itself. 90% of the time it is a safety switch such as a float switch (drainage problem), which cuts the power to the system to p ... Honeywell Air Conditioners

Lennox hvac wont turn on. Not even the fan. replaced thermo and still nothing. checked all breakers too


There is a fuse or small circut breaker on the board ... Air Conditioners

Air conditioning unit not running but fan keeps running even though thermostat is turned to off, auto, and temp set to highest position 90degrees. 3 amp fuse keeps blowing on the circuit board in the blower compartment. I replaced it 3 times then installed a new thermostat. no change. I can usually figure it out if I got a little input or direction. Any help would be deeply appreciated. I would much rather have a trained expert easily repair my hvac unit but I can only call the professionals in


If the fuse is blowing then this is generally indicative of a short in the low voltage wiring, isolate the wires on the thermostat and the unit ends, use an ohmmeter to verify that there is no path for continuity with no wires touching, if there is t ... Air Conditioners

Have had ice and snow here in ATL. Today heat in Weather King RCBA 3765 GG17 would not come on. Checked Breakers, A/C breaker was tripped. Reset breaker, checked for ice in condenser (W/K 10PJA 3701), made sure I was getting 230 V to HVAC in attic, jumpered Y to G to see if blower would turn on, but it would not. Blew out condensate line and checked for ice in the inside unit coils. Acting like a limit or door switch is open, but I don't see any such switches. Anyone got any advice? Thank


Try R to G instead. The red is the 24v side. Greeen is the blower. You should also have 24v ac between r and c (brown or black) at the air handler. You can check at the condenser for power also. Turn the unit on at the thermostat and go outside to ... Weather King 10PJA2501AH Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific