Missing fault code legend

\015 I cant find a faut code legend for a carrier a.c model #FA4CMF036, could u please help\015

Answers :

Http://www.carrier.fi/dm/file.phtml?id=84
\015\012
\015\012This should be what you are looking for.
\015\012
\015\012If so, please rate this post.
\015\012Thank you.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Missing fault code legend


Http://www.carrier.fi/dm/file.phtml?id=84\015\012\015\012This should be what you are looking for.\015\012\015\012If so, please rate this p ... Carrier Air Conditioners

When I turn the air conditioner on, the indoor blower runs for about 10 seconds and then stops. After which the red fan symbol on the evaporator section blinks and no condenser. I don't have any fault code legends for this product. TAS-24H


Sounds like you may have a shorted capacitor on the fan motor. Hopefully not the motor itself. The capacitor should be in the electrical box and looks like a battery. ... Turboair TAS-24H Split System Air Conditioner

I have the error code A77 on my ariston microgenus HE 28 boiler. I have looked at the fault chart and it gives you 3 options but does not tell you how to repair or test any of them. I have empted the condense trap and pushed the reset button but the fault code is still there. any ideas????


... Air Conditioners

Ecu-Maxx Marine Air-Con. Compressor Load Fault Code (CLF) appears. Air Condition turns on but then after 2 minutes, I get the CLF code. Manuarl says it is Compressor Load Fault. How do I fix this?


Clean the filter on the water pump. It may be clogged. Even if there is just a little bit of gunk in there it can cause this error. ... Air Conditioners

Unit in room displays fault code -0 and 6. Unit is a Sharp eco inverter AY-XP07ER. Unit runs for a few minutes and cuts out showing fault code.


Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.\015\012\015\012Using ... Sharp Air Conditioners

PANASONIC CU160C53XP FAULT CODE F33 COMES UP ON KEY PAD WHAT DOES IT MEAN HOW CAN I OBTAIN FAULT CODES FOR THIS UNIT THANK YOU FOR ANY HELP


BEST WAY IS TO GET AHOLD OF THE MFR'S TECH SUPPORT LINE EASILY OBTAINED FROM YOUR SERVICE MANUAL OR INFO (NOT SURE OF STATE) ... Fedders A6P09S2A Air Conditioner

Vulcan eco 120 stoped working, checked fault codes and it said hot serface igntier. i changed that and tryed operation, unit still dose not light. when i press reset fault codes say failure to light, but sometims it also says slow closung gas valve. how can i fix it?


... Air Conditioners

Error code EO fault code


... Air Conditioners

I got a panasonic inverter a/c cs-e12eku with fault code f91and another one with code f90 what are this codes.


... Panasonic Air Conditioners

F0 Fault Code on a Shinco heat pump. What causes this fault? Is there a service manual or any technical information available to help a trade person correct this fault.


... Air Conditioners

Where can I get hold of the AMCOR dual split unit (SF15) "F" fault-codes?


They are in the user manual, or on the panel by the control board. ... Air Conditioners

Fault code for Fujitsu split sytem ASTA24LCC


... Fujitsu Air Conditioners

My ariston boiler displays a red light and A01 fault code. It fails to ignite. Sometimes I can press reset and it will light but this is rare and at mostly even the reset won't get it to reignite. The booklet helpfully tells me it is an ignition fault, but what is causing it?


... Air Conditioners

I have a fujitsu air conditioner cassette type AUT. A erropr code 0.09 is showing. what is that error? and do you have a list of all the codes and related faults.


... Fujitsu Air Conditioners

Yonan Split Air Conditioning System is showing a F6 Fault. What is the fault code related to


F6ambient temp.sensor of outdoorfault1?Check whether the resistance of sensor is normal,otherwise replace it.2?Check whether the sensor wire is short circuit or opencircuit, and whether the plug is well ... Air Conditioners

Pace Air 24HPEW-HEC Unit will not heat, though heat mode comes on, dehumidify and cool mode work, and fan works as advertised. Fault Code E4 presents at startup. Manual is off site. What is this code telling me?


If unit displays "e4"1? Check whether the winding resistance andoperation current of the compressor are normal.2?Check whether the high and low pressure is normalwhen the unit is running.3?Check (whether the ... Pace 12ACXWHEC Split System Air Conditioner

Boiler in Fault with Ionisation fault code. Can I clean the probe?


... Air Conditioners

I have a DeLonghi CF210 and I'm getting the "E3 Fault" code on the main screen. It will not power up in Air Conditioning mode, but the fan mode will run. I saw where someone suggested it is a voltage problem, and have tried it in several outlets to no avail. This problem happened to me about a week ago and I turned it off for a while (10-20 minutes), then turned it back on and it worked again for a week before giving me the E3 Fault error today. I do not have the financial resources to sen


Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power ... DeLonghi CF210 Portable Air Conditioner

I have a Samsung AQV12JA. Fault code (Gas leak) have replace the outdoor and indoor thermistor per tech line. They said replace outdoor computer board. Board was back ordered for over a month, this is a brand new unit so they sent a brand new outdoor unit. Installed it and get the same error code, any ideas?


Hi,As per the error code there should be gas leak from the Air Conditioner. Please visit the link below for a complete service manual with diagrams for more details, I hope it should help:http://tinyurl.com/23ufvr2 ... Samsung AS18A6RB Air Conditioner

I have a panasonic cu-80c52hp air con unit with a fault code of IF42 the system will start up and start cooling then after a bit switches off the compressor and will not switch back on till you turn the system off then back on again, what is the code IF42


... Air Conditioners

Mitsubishi mr slim mn PUL18EK outdoor, PL18FK2 indoor. Getting Fault code P8. wires connected,correct phasing. OA thermister 4160 ohms. 77deg oa and room temp 77deg F.Large line 62.9 deg F at outdoor unit and small line 49.8 deg F. Unit drawing 6.9 amps...Why is customer getting the P8 failure code?


8 flash is a pipe temperature error. ... Mitsubishi Air Conditioners

I have a panasonic cu-80c52hp air con unit with a fault code of IF42 the system will start up and start cooling then after a bit switches off the compressor and will not switch back on till you turn the system off then back on again, what is the code IF42


... Panasonic Air Conditioners

Hi its mits FDCVA402HENAR and the fault code shows I/U NO 00 PROTECT STOP can you please tell me the fault thanks SHERBET


... Mitsubishi Air Conditioners

T078 and T077 fault codes on a gemini 38APD chiller keep noccurring but are not listed in their manual. What are these faults?


... Air Conditioners

Worcester bosch greenstar 30 cdi (system boiler with internal diverter valve), problem = after 15 min self diagnostic, boiler fires then dies, fires then dies & then gives a A6 fault code. technical suggest primary NTC fault. not sure as it fired well in service mode.


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0322 seconds