Having problems with your Air Conditioners ?

Central ac compressor fan doesn't turn

\015 Model ye036g\015

Answers :

If it is the capacitor, on the top of it it may look swollen instead of flat.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a goodman 4 ton central ac unit. The fan blower turns on but the compressor will not turn on. I replaced the capacitor and verified the compressor is receiving power. My question is a goodman compressor hard wired on the bottom or will I be able to easily checked The wires on the bottom of the compressor ?? Thank you for Any help you can provide Thanks again


Hello, you can Ohm the compressor windings with a multimeter. Just kill power the the unit, remove the wires from compressor and check each winding. You should have resistance, if not the windings are open and compressor must be replaced. ... Air Conditioners

COLMAN TSR I JUST BOUGHT A HONDA EU 3000 IS THAT I WAS TOLD SHOULD RUN MY AIR CONDITIONER WITCH IT DOES FINE UNTIL THE COMPRESSOR STARTS CYCLING. WHEN THE COMPRESSOR TRIES TO TURN BACK ON IT TRIPS THE OVERLOAD ALARM. I HOOKED IT TO THE HOUSE AND IT DOESN'T TRIP THE CIRCUIT BUT WHEN IT TRIES TO CYCLE THE FAN DIES ALMOST ALL THE WAY OUT FOR ABOUT 5 TO 10 SECONDS THEN THE FAN STARTS RUNNING OK AGAIN BUT NO COLD AIR FOR ABOUT 30 SECONDS THEN IT CLICKS FAN DOESNT CHANGE AND COLD AIR RESUMES. THAT LAS


3000 Watts is a little short on the power necessary for the compressor to restart. When it compressor starts it may draw 27 amps or more for a split second. 3000 / 120 = 25 amps. when the fan slows down it is telling you the voltage has dropped and i ... Coleman Mach 15 Air Conditioner

My a/c stoppped working, model fas257s2a, compressor doesnt turn on I thought it was the boards replaced them still doesnt turn on fan works but comp. does not kick on, checked capacitor 40/8 reads 39


... Frigidaire FAS257S2A WallWindow Air Conditioner

My central cooling system does not work. Every things is working accept a compressor. When I turn on the cooling system the compressor makes strange nose and after one minute it turns off, but fan kips continue to work. Do you have any suggestions for me? Thank you Model # of my air conditioner is CCU10A42A-1


Compressor overload on the compressor ... Air Conditioners

I turn on the Central A/C unit with the thermostat. The attic fan unit goes on and the system cools the house. When the system shuts down the fan unit shuts off but the outside compressor keeps running. The only way the outside compressor goes now off is when I flip the 240 switch on the main box. This just started. Is it a thermostat problem? Thanks.


Could be a thermostat problem but even more likely the contactor on the unit outside is stuck. In order to change this part you will have to get in to the outdoor unit. The contactor is the automatic switch that the thermostat energizes when the t ... Air Conditioners

Have a 3 year old york central air system, used very little. Turned on --- compressor runs, but fan to cool compressor will not run. What is it? I doubt the fan motor is bad?


Most of the time if the compressor runs but not the fan, it is one of two things either burned/broken wires causing bad connection or bad capacitor. Simply replace capacitor with a capacitor with the EXACT same specifications and you are good to go. ... Air Conditioners

Compressor kicks on but fan doesnt turn on. Fan freewheels fine


Need to look at the name plate glued to the unit, most units are 220 volts AC. ... Dometic Rooftop RV Air Conditioner

When we turn on our central A/C the fan comes on & the compressor comes on for about 10 seconds & quits


Sounds like a compressor problem to me.Have you tried a hard start kit?This increases the starting torque.Put an amprobe around the common wire to the compressor and see the amperage draw is on start up.It sounds to me the compressor is cutting off ... Ruud UAKA042 Air Conditioner

The fan ouside doesnt turn when the system requires, the compressor contactor clicks but does not set the fan motor running


Change fan capacitor. ... Air Conditioners

I have a 1979 general electric central air unit that the compressor runs but the coolant fan won't come on. The fan turns freely by hand. Any tips? The model number is BTN924A100A3


It could be a bad motor or capacitor. It also might not be getting any power. If it uses a head pressure switch or a condensor temp control to slow the fan on cooler days, it could be that also. ... GE Air Conditioners

I have a coleman electraheat rv airconditioner/heater. i think the thermostat has gone out on it. is this a replaceable?When i turn the thermostat knob nothing happens. the fan will run but the compressor doesnt engage if it is not running or will not disengage if running...however if i tap the thermostat housing it usually will activate the compressor...is the thermostat unit replaceable and if so where may i find one


The thromstat may be bad but it sounds like there is a loose connection where the wires plug on to the back side of the thromstat.\015\012\015\012Any RV dealer should have the part or be able to order it for you ... Dometic Rooftop RV Air Conditioner

Compressor wont turn on. fan runs central unit


First check you thermostat settings and make sure that it is on a cooling setting if ok it can be the fuse that sends the power to the outside unit if fuse is ok it can be the capasitor for the compressor if ok you may have to check the compressor fo ... Amana PTH153B50AE Air Conditioner

3 ton heatpump package unit kicks 100 amp breaker compressor hums and condesor fan doesnt turn


Compressor is locked up! check the start relay and the fan motor to see if the shaft wobbles up and down if it don;t! then replace the compressor ... Air Conditioners

Central ac compressor fan doesn't turn


If it is the capacitor, on the top of it it may look swollen instead of flat. ... Air Conditioners

UNIT RUNS AN EXCESSIVE AMOUNT OF TIME AND AIR IS COOL NOT COLD COMING OUT OF VENTS CARRIER 58DLA / 58DLX CENTRAL AC FAN AND COMPRESSOR ARE OPERATING BLOWER IS WORKING UNIT IS TURNED ON TO AC TEMP SET AT 76 UNIT RUNNING FOR OVER AN HOUR OUTSIDE TEMP 80 THERMOSTAT REGISTERING 77


DOES THE HOUSE FEEL DRIER IF IT IS 80 OUTSIDE WITH ALOT OF HUMIDITY THE UNIT WILL RUN FOR A LONG TIME TO REMOVE THE MOISTURE(HUMIDITY) OUT OF THE HOUSE BEFORE TEMP DROPS DRAMATICALLY IS THERE WATER COMING OUT OF THE DRAIN PIPE OUTSIDE ... Carrier Air Conditioners

Compressor hums but fan not turning. Pushed fan to


Cap most likley ... Air Conditioners

I have a air compressor that I know the fan is bad in the outside unit. The compressor is not turning on. Yesterday the only way that the fan would run is with a push, now today it won't run at all. If the fan is not at full strength, will the compressor turn on. I want to know if I need a new air conditoner or is there hope in fixing this unit...


There is definitely hope in fixing this one as long as its just the fan not working. Carrier can easily fix it for you if you want. If you are looking for any more specific information, I would be glad to help but I will need the model number of the ... Carrier Air Conditioners

I have a Haier HWR05XC7 that will NOT work. The compressor turns on, but the fan won't work. The fan moves freely because I tried moving it with a screwdriver, but when I turn the unit on, the compressor kicks on, but no fan. I have been fighting with this thing for weeks and am about to chuck it out of the window. Also, the red error light stays on and there is nothing in the manual on how to troubleshoot it (other than making sure it is turned on and plugged in!). No support from Haier or Circ


HEY< If you start out having problems , what do you think the future of that unit will be! ... Haier Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

Hi there, iwant some help in duct type air condition (trane)60000 BTU .when i was gave the out door freon i recognized that the high pressure fans were off and the compressore was on ,so i turn off the air condition for seconds then turn on i found that the high pressure fans run for one minute and then turn off and the compressore still running ,so what i shell do????


I hate to say this but it sounds to me like you need a professional. You may hear some other advice but it's not safe for anyone to work on the outside compressor unless they really know what they're messing with. The fire and death by electrocutio ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

We turned on our 1.5 hp air con Fujita on the heat setting, the compressor would run but the fan would not work. The compressor became noisier so we turned it off. On the cool cycle the compressor ran and the fan but it did not seem to be cold. This unit is brand new.


The compressor got noisier be cause the head preasure was going up putting a strain on the compressor check all your wires from the fan motor and make shure they are all hooked up and than check the capacitor for the fan it may be bad usualy it will ... Air Conditioners

5,200 BTU unit. Compressor and fan both work when first turned on, then compressor quits after 5-10 minutes of operation. Won't turn on again even after 5-minute fan-on cool down. Process repeats after AC unit has been turned off for 10 minutes and re-started. Is this worth trying to fix, or should I replace the whole unit?


This could be just a simple fix of cleaning the condenser coils. If semi-clogged, it can cause higher than normal pressures and cause the compressor to cut out on it protector. Check it out. ... Air Conditioners

Fan not running on central air unit, compressor runs. Old model, btr936a100b0 central air, the compressor runs, but the fan does not. I need to find out what to check to troubleshoot the fan motor components


... GE Air Conditioners

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

My fedders aircon compressor does not turn on again whenever its thermostat turns it off. what i had to do is unplugged the power cord and turn it on again to work. i already replaced the capacitor. what i observed is that the big normally open rely does not switch on. maybe a board problem? if i turn it off and turn it on again, only the fan rotates and not the compressor. i had to unplug the power and put it back again for the compressor to run again.


You have a time delay build in on the pc board of 3 minutes. If it takes longer than 3 minutes check your compressor overload protector, Maybe the compressor is overheating, check your coils for proper air flow. ultimately if the compressor checks ok ... Fedders A6X05F2D Air Conditioner