Blower will not kick on

\015 My blower will not kick on it has voltage to all leads and the motor is very hot.. jsut before this happened my systems A coil froze up ..\015

Answers :

The a-coil froze because of no air flow.
\015\012Let the motor cool down.
\015\012Then,
\015\012Check the capacitor to the blower motor.
\015\012If it is good, replace the blower motor.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a magic chef ultra 97 furnace. the blower started making a noise. i removed the blower and blowed the blower out with air and lubed the back bearing with pb blaster. reinstalled blower. the blower kicks on and works fine, but the furnace won't kick on. when the furance kicks on and both the blowers start, but the pilot light dosen't try to ignite.


U may have a bad ignitor or u might not have hooked up a safety switch or u may have accidentally caused a sensor to go out not knowing but it sounds like the ignitor is bad is it a glow plug or does it spark to light ... Air Conditioners

My heater is not working. When the thermostat is placed in HEAT mode, it sounds like the blower is kicking on - but then it shuts down a minute later. I looked in the unit in the attic, and I can see that what appears to be a small blower kicks on (a black circular wheel starts spinning) but then I do not ever get a spark - it just all shuts down. Is there something I can check myself (pressure switch, fuse, etc) with a simple multi-meter before having to get a service man?


Yes. First go into the attic and look thru the the inspection hole in your furnace. It is a small hole with a glass cover you can look thru. Therer will be blinking light inside. The numrer of blinks tell you that what the problem is. Example three b ... Weather King 12AJA4801AH Air Conditioner

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Have a 1/2 horsepower furnace blower motor that will not kick on when it is suppose to the fan on the blower makes a loud buzzing noise. Could it be sticking or a bad capacitator? At times I may put my hand in the blower and spin it to get it going.


Hello, sounds like you capacitor is bad and needs to be replaced. ... Air Conditioners

AC is cooling, just had the capacitor replaced, but the blower on the furnace continues to run. Also just had the thermostat replaced. Thermostat is set at 79, house temperature is 75 and blower kicks on. Does this have to be fixed immediately or is it ok for the blower to run?


It will hurt nothing for the blower to run continuously. Make sure the thermostat is not set for the blower to run all the time. You can turn the blower to automatic or run. Set it on auto. ... Frigidaire FAA065M7A Air Conditioner

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green blower wire terminal (removed the green thermostat wire) the blower fan runs (non-stop) & igniter & burners restart every 10 mins. when I remove the jumper (& wire to specs from the thermostat to the furnace) igniter & burners kick on for 90 seconds then nothing on the unit works except the exhaust f


... Air Conditioners

My intertherm electric furnace blower will not kick on during heating only


... Intertherm Air Conditioners

Goodman Air unit - Blower Fan will not kick on


Same problem....any solutions yet? ... Goodman CKL60AR60 Air Conditioner

Carrier Furnace LED Good, Blower does not kick on


... Air Conditioners

Blower won't kick on


My guess is the FAN RELAY has loose contacts in it Trace the wires from the motor to where they tie in 1 will go to the power cord (this in L2 or Nut) The other 1 or 2 wires will go to a fan swich/relay or a rotary hi limit fan acutator sw. This rota ... Air Conditioners

I have a trane xe 90 and blower does not kick in but blower spins free by hand what causes this


... Air Conditioners

Enviracaire filter system makes squealing noise when blower fan for funace kicks on


... Honeywell F200E1037 F200E Media Air Cleaner 20x25

I have a ruud furnace/airconditioner Model:UGPN-07EAMER, Serial: FU5D302F390401344. When the thermostat calls for heat, a little motor (within the furnace itself) or something kicks on, the burners ignite a few seconds later, then the blower starts. It's at this time the flame goes out and the blower is just sending cold air throughout the house. There are two green lights (power and ok) lit normally and the orange(ish) blinking "flame" light on the main board. When the flame goes out, the


Hi, this motor is the inducer motor, which is the first thing to start on a call for heat. Everything seems to be going through its sequence of operation just fine, but then shutting down on a safety. Look on the panel for a chart that should tell yo ... Air Conditioners

I have an old RUUD central AC unit that started blowing hot air. I set the thermostat to off and set the temp gage higher than air temp to turn the unit off and save money, but inside blower unit runs constantly. I'm trying to save money to have it serviced, but noticed my electric bill was higher that last month when the ac was working. The bill was about 4 times higher than the winter when ac is off and the gas heat kicks in. Can the blower running constantly cause this power usage and what is


HelloOkay did you check your thermostat to see if you have the fan switch on auto? The switch must be on auto or the fan will continue to run. If the thermostat fan switch is on auto then there is a malfunction in the thermostat probably ... Air Conditioners

I have a Goodman model A36-10C Indoor airhandler with an intermitent problem. Sometimes when the AC kickes on the evaporator will freeze up and the evaporator blower will not operate. Was told it might be a time delay blower relay B13707-38. Does this sound correct?


... Air Conditioners

I have an Amana model number pgb 30c09020. It quit working about a month ago and if you pushed on the fan on the combustion blower, it would come on and work for a while. They got the code and replaced the combustion blower. It worked a week or two and then it started going off. When it gets to the temperature, it kicks off and will not come back on. If you flip the breaker off and back on, it will come on. Also, if you leave the door off the flame will stay lit. If you put the door back on it,


Since everything seems to work when the door is open is an indication that the inlet air filter if blocked. Remove filter and clean it with a vaccum cleaner. IF the filter is clean check that the air inlet itself is not blocked by a peice of furnitur ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a rheem prestige series contour comfort control natural gas furnace. At the end of the heat cycle the unit will shut off, then the blower kicks on to cool off the heat exchanger. It will actually kick up on high fan speed to exhaust the heat. The unit is only 3 years old and it did not do this before.


Make sure that your furnace filters are clean it sounds like it could be cycleing on high limit. ... Air Conditioners

Furnace will not light burners and blower motor doesn't come on, but exhaust fan comes on immediately when turning furnace on. Turned on A/C to make sure blower operates and it does. The combustion chamber door says there is a red button to reset inside, but the only thing I can find is like a thermistor with maybe a button on it and it is not kicked. What should I try next?


The reset button should be a small round red button that you just push in to reset. If the induced draft motor comes on as soon as thermostat calls for heat then the next thing to check is the ignitor. It may be a hot surface or spark ignitor.It shou ... Air Conditioners

My blower blew a 3 amp fuse..i replaced it....the blower is running...but the ac wont kick back on


Not sure what fuse blew. But if it is a Carrier unit, look at your circuit board, ck for a small red light on the board, see if it is on and flashing. Look on your board for the flash code. That will tell you basicly whats wrong, place to start. ... Air Conditioners

Hello i have Carrier Weathermaker 38tkb air conditioner unit. It's about 6 years old and when i got home today, the unit itself wasn't working. Although the blower fan in the furnace inside was blowing, the fan on the a/c unit outside was not moving. I can hear a humming sound coming from it and once in a while, you hear it trying to kick in (the lights in the house even dim a bit, which is unusual), but it never kicks in. The top center of the unit is extremely hot to the touch. I've checked


The humming noise and dimming of the lights is an indication something in the outdoor unit is locked up or has failed.Check the capacitor as it may have gone bad. If the capacitor is good, then you either have a failed motor, a failed co ... Air Conditioners

I have a problem with my heating system. It is about 10 years old and has had the ignitor, combustion blower motor, and programable thermostat replace in it's lifetime. The system worked great last year. This year has not been so good. The system was checked and cleaned last month. What is happening is the blower kicks in and the burner cut off after a few (15-20) seconds. I tried shuting down system and turning off power to reset. When you turn heater on this is what happens 1. Combustion fan c


Sounds like its not proofing flame. it has a sensor usually like a needle sticks out into the flame that tells the gas valve the flame lit and is burning so its ok to keep sending gas, if its fails to proof flame then burner shuts down, then it tries ... Air Conditioners

Amana gas fired warm air furnace. Blower (fan) works fine when thermostat set simply to "fan". When selector is moved to "heat", burner fires nicely but teh circulatior blower fan does not kick-on. Any suggestions?


Either bad run cap on motor or bad blower motor ... Amana Air Conditioners

I have a Inter therm Model# FEHB015HA central heat & air unit that I had problems with in the summer as the out side unit would not come on but the blower would kick on but nothing on the outside unit(No cold air).Ok I fixed that as it was the the transformer that switched it down to 24 volt to go to the outside.Now I have noticed that when the heat is on it will not kick the outside unit on?It has been very cold here in Georgia but right now as I type it is 50 degree's and the outside unit is s


Hi, if this is not a gas fired split system, it is a heat-pump with aux heat strips. The outdoor unit must be on to warm you're home by way of the reversing valve. The strips in the indoor unit are for emergency and auxiliary heat only. ... Air Conditioners

My 8 yr old Amana heat pump, model RHE48A2D with Honeywell progammable thermostat in heat mode has the blower running constantly. When there is a 6 to 8 degree differnce between room temp and thermostat setting compressor runs as it should, the closer it gets to thermostat setting, it will run about 30 seconds, blower continues to run until getting just cool air, about 5 minutes, compressor kicks back on for 30 sec., continues to do this, thermostat shows it has reached set temperature,


Hi, It sounds to me like what you are describing is, that when it is 6 to 8 or so degree difference then the stat says, unit operates as it is supposed to but then before it satisfies the t-stat, it shuts the compressor down long enough to start cool ... Air Conditioners

I have a goodman furnace. The blower is not kicking on for my heat. however if I switch it over to a/c then it blows fine. My furnace works with the blower starting first then the ignitor will engage lighting the propane. what could the problem be?


... Goodman CKL24AR24 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0472 seconds