Having problems with your Air Conditioners ?

Intertherm furnace model MGHA070AAFC-01 cuts on and off

\015 When the temp drops the frnace keeps cutting on and off until I turn the fan switch off and wait to hear a click and then most times this fixwes it but not always\015

Answers :

I assume this is a gas furnace? If so its most likely your fan switch. This is set to come on after the "Chill" is gone on the furnace and go off a few moments after the flame cuts off. there are several different kinds but you will find it if you trace the wiring from the fan motor (usually the colored wire red, blue, or yellow and NOT the black or white or brown) goes to it. If the colors are hard to see use a good lite and some alcohol to clean them up some.

Hope this helps and please rate me accordingly Good Luck.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Intertherm furnace model MGHA070AAFC-01 cuts on and off


I assume this is a gas furnace? If so its most likely your fan switch. This is set to come on after the "Chill" is gone on the furnace and go off a few moments after the flame cuts off. there are several different kinds but you will find it if you tr ... Intertherm P3RA-048K Air Conditioner

I have a Central Electric Furnace for Mobile it is an Intertherm Model FEH-015 HAC-04 Serial # FEH-9101-0237 It needs to be replaced, I'm wondering if you could help me in providing a model that can replace it.....I always have to turn my old furnace off at night as it is so loud it wakes me up and is there anykind that are more quiet now and maybe more efficient? Is Intertherm furnace better than a Trane ? Thank you in advance for some help with my problem. Michelle


... Air Conditioners

I have installed a UPM model THM101B thermostat on my Intertherm model E3EB-015H electric furnace. I wanted the feature of turning the blower "ON" without the heating elements. I picked up the green 12v for the fan relay. Once the power is restored the furnace comes on even though the temp setting is low and the only way I can turn the furnace off is by disconnecting the green fan relay wire? The jumper has been properly set in the new thermostat for electric furnace operation.Right now I feel t


... Intertherm Air Conditioners

I have a 1987 intertherm model mgh 075 aacw 05 furnace in my mobile home. What is the efficiency rating of this model?


... Intertherm Air Conditioners

Intertherm gas furnace model - MGHA-077ABFC-05 Our pilot is lit but the furnace won't kick in. We have used it once already this year and it worked just fine. Any help is much appreciated. We really want to avoid paying for a costly diagnosis and repair. Thank you


... Intertherm Air Conditioners

Intertherm Electric Furnace in mobile home Model# MRAC 2317 SN - 79JE0501 Question: The blower stays running all the time. I have to turn the main breaker off to turn the blower off. The unit is heating when it is running. I have replaced the thermostat about 3 years ago in the summer when I had a AC problem. Would the fan switch on the furnace possibly be the problem? It has an auto & on position on the switch. It clicks when you switch to the on position but does not click when you put i


... Intertherm Air Conditioners

Outside unit will not turn on. Inside fan works fine. This intertherm unit is an upright, 6yrs old. Model number unkown. Fan will turn. No hum coming from unit. inside condenser sits on furnace model # E2EB-015Hb. Freon charging is outside on the lines coming from outside unit.


Hi! You may want to start on having the power supply checked. Good cause why the unit won't power up. Have the compressor checked too just to be sure. ... Intertherm Air Conditioners

Intertherm gas furnace 80 % mod# MMHA-070ABHR-05 will not open gas valve and light <changed gas valve <control board<ignitor all three limits and still not working I have been in the hvac buisness for 10 years but cant solve this one ,the board is flashing a 3 code < i have called a fellow tech who had the same problem on the exact same model last year and he spent 10 hrs trying to repair this unit but was unsuccesfull also<i can make this furnace burn by wiring 24 volts direct t


... Intertherm Air Conditioners

Intertherm gas furnace model number m6bb070abfc01


Sounds like there is no signal from the thermostat. Take a jumper wire and place it on the R and W terminals in your furnace. Make sure that the door switch is taped down. This should start he burner. If it does, start looking for a blown fuse, bad t ... Intertherm P3RA-048K Air Conditioner

Intertherm gas furnace model# MGHA-070ABFC-05


... Intertherm Gas Furnaces - M1GB-056-AA

Intertherm furnace model # MMHB-070ABHR-06 red light blinks two times


Number of flashes mean different things for diff models. The meanings of those flashes should be posted somewhere on the unit; usually inside front of the bottom service panel. Though you can't truly diagnose a problem by number of flashes they can g ... Air Conditioners

How do I stop my intertherm furnace model # MGH065ab fan from making so much noise?


... Air Conditioners

Intertherm model e3eb020h electric furnace won't start just hums


Check fuses. one may be blown, and the other one not, Therefore you are getting only 110V to a 220v circuit.\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012\015\012 ... Intertherm Air Conditioners

Intertherm model MGHA-090ABPQ-01 ac works, furnace won't come on, all it does is humm when I turn it to heat. works okay on ac. Pilot light is lit and is on, what could be wrong?


... Intertherm Air Conditioners

HELP......! Have a gas furnace . It doesn't say what it is.... I believe it is a coleman, or intertherm the model number is DGAT070BDC serial # is 940465330 that is the only information it has on it. Someone apartly tried to make it work, and all of the wiring is undone or gone...board is gone. and I am not sure what else.... Is there a way you can get the wiring scamatics for me.... and possibly a listing of what parts should be in it.... Please help! let me know...at: jarvissonsinc.att.net If


You might try a Coleman or Intertherm dealer in your area, they should be able to help you or maybe go online to those companies. ... Carrier 36KCARMS Air Conditioner

Manual 4 intertherm furnace model EDM4X36FA2 ?


... Intertherm Air Conditioners

I am looking for a manual for an Intertherm Furnace model # C3QA-042U-B


... Air Conditioners

I have a Intertherm heating and air conditioner it is a Manufactured Home. The furnace model number is E2EB-017HA. When you flip the switch to heat and move the control arm up nothing happens. You can go all the way to the top and still nothing. Now if you flip the switch to on it will come on. Or if you flip it to cool and move the control arm down it will click and come on I am not sure what to do. Jerry


When you turn the on/off switch to on you are turning on the "fan switch" and the blower motor is only coming on. When you turn the switch to cool and move the tempature control lever down you are turning on the air conditioner...So it sounds like yo ... Intertherm Air Conditioners

1990 Triple E mobile home with an Intertherm model MGH-075AACWN-06 furnace. Pilot would not stay lit unless I heated thermocouple probe with a propane torch a little more than the pilot flame would last winter. This year it will not stay lit at all. Do I need a thermocouple? Where can I get a manual or repair instructions?


I've a similar problem and a new thermocouple solved it\015\012\015\012J. N. Millet, Alberta ... Intertherm Air Conditioners

I have a intertherm furnace model mac1175 series, it's blowing lukewarm air, how do i get hotter air ?


There are two motors in an AC. One is the fan motor and is controlled by a switch. The other is the compressor motor. It's operated by the thermostat. If the thermostat doesn't work you'll only get warm air (cooled only buy the fan) because the c ... Air Conditioners

Intertherm electric furnace model e2eb-012ha is blowing only luke warm air. I have checked thermostat settings and air filters. Need help on next steps.


... Intertherm P3RA-042K Air Conditioner

I need the installation manual and/or wiring diagram for the Intertherm Furnace model: FEH-020HA-03, please.


... Intertherm Air Conditioners

I need the wiring diagram for my Intertherm central electric furnace, model number FEH-015 HA with central a/c. I am having relay problems and thermostat wiring problems after my fan motor had to be replaced. Thanks!


... Air Conditioners

Where is the capasitor located on a intertherm furnace model #431890


Next to the compresor in the condencer ... Intertherm Air Conditioners

How to replace an intertherm Furnace Filter model MGHA-070AAFC-05


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0610 seconds