Furnace runs OK, but blower runs again a few seconds later

\015 Happens more when cold, as in the morning or real cold outside temps. Furnace will run & heat normally, but after it shuts down, the blower will start up a few seconds later and run for only a few seconds. Usually once, sometimes twice in quick succession. Furnace is Carrier forced air, about 18 years old. Technician states ''that is what old furnaces do'', cleaned it, checked plenum for cracks, all OK.\015

Answers :

Could be a defective thermostat in the plenum.
\015\012When a gas furnace shuts down the fan(blower) will run until the plenum cools to the safe range. Usually 1 and 1/2 minutes.
\015\012Intermittent operation is a defective thermostat or relay.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The Coleman Mach thermostat in my 5th wheel blows its 2 A fuse a couple of times today and am trying to figure out what is causing this. Please help. I am unable to get the furnace to run even with a good fuse in the thermoatat. When I bypass the thermostat to run the Atwood furnace (red tied to white wire). THe furnace blower comes on and the burner sounds it lights for 5 seconds and then goes out. 15-20 seconds later it reignites and goes out and continues to cycle -- the blower motor


Hi\015\012\015\012Its blowing fuses because of short circuit inside the coleman mach or due to two wires being shorted with each other. You'll need to open up your thermostat system to look for the short circuit and also shorted wires.Ple ... Air Conditioners

Furnace runs OK, but blower runs again a few seconds later


Could be a defective thermostat in the plenum.\015\012When a gas furnace shuts down the fan(blower) will run until the plenum cools to the safe range. Usually 1 and 1/2 minutes.\015\012Intermittent operation is a defective thermostat or r ... Carrier Air Conditioners

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green blower wire terminal (removed the green thermostat wire) the blower fan runs (non-stop) & igniter & burners restart every 10 mins. when I remove the jumper (& wire to specs from the thermostat to the furnace) igniter & burners kick on for 90 seconds then nothing on the unit works except the exhaust f


... Air Conditioners

Nordyne 624631-8 A/C & Gas furnace contr board has a blinking red 'Status' light. Goes On, off 2 seconds, on, off 2 seconds, on, off 2 seconds, etc. The trouble codes on my wiring diagram are worn away...help r The unit runs for a bit, once, then cuts off and the blower motor runs forever. Unit works fine on A/C.


On the heating side this happens if you are having a problem with the high limit switch. The unit will heat up and burners will run for awhile,shut off and the fan switch will close and run for ever to cool the heat exchanger down.Make sure the filte ... Air Conditioners

My Ruud furnace blower motor runs and gas is ignited but after 3 seconds the burners go out. The blower still runs and it keeps trying to ignite and then goes out every minute or so.


Sounds like a dirty flame sensor, on thenopposite side of the igniter there will be a metal rod, clean this rod with steel wool ... Ruud Gas Furnace - Excellent Condition - $350 Obo

I have a new CMF2 80-PO convertable the blower comes on with the heat but sometimes shuts off and on and on the cool down it will run for 2seconds and shut off and 1 second later the same thing what is the problem? should the blower run longer it sound like the motor will not last long if it keeps working this way.


... Coleman Intertherm Nordyne Miller Furnace Control Board 904531

I HAVE AN OLDER 80000 BTU WESTINGHOUSE OVERHEAD GAS FURNACE IN MY GARAGE. LAST WINTER I HAD A PARTY AND HAD THE FURNACE ON, BUT LATER IN THE NIGHT I NOTICED THE CIRCULATING FAN WAS KICKING ON AND OFF WAY TOO MUCH. THE BURNER WAS LIT BUT THE FAN WOULD RUN ABOUT 10 SECONDS AND SHUT OFF FOR 20 SECONDS AND KEEP REPEATING.I'M GUESSING ONE OF THE LIMIT SWITCHES IS BAD BUT I DON'T KNOW WHICH ONE OR WHERE IT WOULD BE.HELP WOULD BE GREAT!


... Air Conditioners

I have a ruud furnace/airconditioner Model:UGPN-07EAMER, Serial: FU5D302F390401344. When the thermostat calls for heat, a little motor (within the furnace itself) or something kicks on, the burners ignite a few seconds later, then the blower starts. It's at this time the flame goes out and the blower is just sending cold air throughout the house. There are two green lights (power and ok) lit normally and the orange(ish) blinking "flame" light on the main board. When the flame goes out, the


Hi, this motor is the inducer motor, which is the first thing to start on a call for heat. Everything seems to be going through its sequence of operation just fine, but then shutting down on a safety. Look on the panel for a chart that should tell yo ... Air Conditioners

Hello, I have a Amana Air Command 80 model #GHI90A50, 22 years old. This furnace is on its third ingnition module (last one two yeras ago). The symptom I am trying to diagnose has been ongioing since this latest ignition module was installed. The furnace is short cycling, meaning it runs often once every 8minutes but for less than 3 minutes at a time. The sequence is as follows: Cycle start (small blower turns on), followed by the ignition module illuminating (yellow) for 3 seconds then turns g


If your furnace lights and the gas stays on for 8 to 10 seconds, then shuts \012right back off, then you need to clean your flame sensor with light sand paper \012or steel wool. You might need a new flame sensor, but most of the time th ... Air Conditioners

My Goodman GMP100-4 blower fan runs slower than the second unit. The blower did not start when I turned the A/C or furnace on. However, if gave it a push (spin) from the side, it started turning, but at a slower speed. hardly any air blows from vent. Will capacitor replacement solve the problem? Is slow speed also due to capacitor?


Replaced capacitor and cleaned filter. Problem solved. ... Goodman Air Conditioners

Amana Gas furnace, Air Command 80 SV. Does not ignite. The blower turns on, then gas valve opens. I can hear a mechanical switch close, which is probably the igniter control. But no spark, no flame. After a few seconds the gas shuts off and then blower shuts down later.


Buy a new ignitor here; The Ignitor Store. Or talk an Amana dealer/Contractor to sell you one. They can range from 15 to 35 bucks! Depending on their mark-up. Give them your model number, and or ignitor part number. Their simple to change ... Amana Air Conditioners

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green b


... Air Conditioners

Have a Payne pg8uaa furnace. Furnace only works when I run a jumper between R and W. Replace wiring to furnace. I suspect that the outside blower motor is the problem. When furnace is running the blower motor has a humming sound but does not blow air. At this point, I would like to know how you would diagnose a Tjernlund HSUL-J blower motor. Should the motor itself be replaced or should the fan prover be replaced?


You would have to test the motor as well as the capacitor on the motor capacitor goes for alot less then the motor though.here is the pdf manual on your blower h ... Air Conditioners

Furnace troubles with my Amana 80SV. The fan kicks on, ignitor (?) glows orange, the gas fires up, and then shuts off 2-3 seconds later, fan still runs, process repeats itself over and over.


You need to bleed your line,if you have a gass button,hold it in for 5min,then try again ... Amana Air Conditioners

Our furnace went into lock out and so I cycled powere and it reset it started working again but not correctly. The inducer motor wis coming on for a few minutes then the hot ignition comes on and the gas lights. then the blower comes on then shortly after the gas cycles off and then a few minutes later it cycles back on and usually the fan alternates on with the gas. I started checking the safety switches that go to hot ignition control. (24V) Once everything was running the 24V would drop to ze


Boy it sounds like a high limit opening up and shutting off the gas valve. It won't shut off the blower because it wants to cool off thge furnace. Check for any restriction in the air delivery system, filter, registers. Check for blockage of the exha ... Air Conditioners

I have a 2 year old Goodman GDS80703ANA furnace that has always had a problem starting. Sometimes it starts on the first attempt but other times it takes 2 or 3 attempts. This is what I see happening: The Induced Draft Blower starts and runs- the Igniter will glow for a few seconds and just as the igniter starts to stop glowing I hear the Gas Valve click and open but it is too late. On the next attempt or so, the Gas Valve will open sooner and burner will ignite. My question is: Is the Integrate


The board controls the timing ... Air Conditioners

The blower in my Ruud gas furnace won't shut off. It just runs and runs. The thermostat is set to "off" and the fan switch is set to "auto". We haven't used the furnace or AC the past few months since we haven't needed it, so it's been in the off position. Then yesterday out of nowhere the blower randomly fired up and hasn't turned off since. It just runs and runs until I kill it at the breaker. The thermostat is about two years old so it's fairly new. I replaced its batteries and that didn't


I'm not sure what setup your unit has but the fan relay sound like it is bad. If your blower connects to a circuit board then the board could be bad. Different units use different ways to control the fan. Some use a relay like I mentioned. Some use t ... Ruud UAKA037 Air Conditioner

I have a goodman furnace and air conditioner. When the air conditioner is running, it runs for about 10-15 minutes, then shuts off for about 5 seconds, then restarts. Could you tell me what would be wrong? I think also associated with this problem, when the heat is running, the furnace will run for about an hour, then shut down, even though the temperature has not been reached. Resetting the breaker, or depressing the reset switch in the thermostat will start the furnace running again. A third p


Try running viniger through it , clean or replace filter , if filter was real dirty you may want to have your evap coil cleaned ... Air Conditioners

Hi, I have Lennox gas furnace Model G12Q3E-82 (about 30 yrs. old). When running the A/C, I noticed there was water leaking or dampness around the bottom of the furnace. I removed the hose from the drain spout on the evaporator and noticed it was plugged and unplugged it to drain some water out of it. I also removed some water that accumulated in the bottom of the frame that wraps around the blower motor and fan wheel. I have a problem where now the blower motor runs for about 1 to 2 minutes then


Hi Todd, you did the right thing by checking the uf on the run capacitor and it is with in range , the reading is good. What is happening is with the condensation building in the pan, the blower motor has picked up some water and burned the windings. ... Air Conditioners

After a power outage and surge, I tried to run the carrier high efficiency furnace "FAN" only to circulate air in the warm house. when I stated the blower, it ran on slower spped than normally.usually cycles between high and balst furnace high....now its running slow.I tried the heat cycle and the blower speeded up a minor amount over just with the fan circulating....is there an internal circuit breaker that could've beed bitten with the surge??


Try replacing the fan capacitor some time power surges zap them.its usually a 5uf or 10uf @ 370vac if you change it and runs fine it was the capacitor if not blower fans keeps slow verify that full voltage is getting to it ex 230 volts or ... Air Conditioners

Intertherm Electric Furnace in mobile home Model# MRAC 2317 SN - 79JE0501 Question: The blower stays running all the time. I have to turn the main breaker off to turn the blower off. The unit is heating when it is running. I have replaced the thermostat about 3 years ago in the summer when I had a AC problem. Would the fan switch on the furnace possibly be the problem? It has an auto & on position on the switch. It clicks when you switch to the on position but does not click when you put i


... Intertherm Air Conditioners

Just installed new Goodman 95% updraft furnace with 3" supply and vent lines going out through wall. Gas valve won't open. Circulation blower runs in manual on, A/C system runs fine. I have used an ohmmeter and voltmeter to do checks. The entire series of safety switches are closed. When the small blower is running, both pressure switches close. The igniter comes on but there is no voltage to the gas valve. Just after the igniter goes off, I hear a relay click, the circulation blower seems


Make sure you have bled your gas lines. If any air is in the lines, it will cause the unit to do exactly what yours is doing. The relay "click" you hear is the gas valve opening, but if there is no gas, it will not ignite. This is common for a new in ... Goodman Air Conditioners

Bryant furnace model 340mav. Furnace filter got extrey dirty due to updates in home. Started to freeze up. Caught it pretty early. Turned off unit. Thawed it out. Turned wl unit to off. Woke up in am. Furnace blower motor running. Code flashing red on furnace. Three quick red. Three longer red. Blower will not shut off unless I turn off manual switch


... Air Conditioners

My 8 yr old Amana heat pump, model RHE48A2D with Honeywell progammable thermostat in heat mode has the blower running constantly. When there is a 6 to 8 degree differnce between room temp and thermostat setting compressor runs as it should, the closer it gets to thermostat setting, it will run about 30 seconds, blower continues to run until getting just cool air, about 5 minutes, compressor kicks back on for 30 sec., continues to do this, thermostat shows it has reached set temperature,


Hi, It sounds to me like what you are describing is, that when it is 6 to 8 or so degree difference then the stat says, unit operates as it is supposed to but then before it satisfies the t-stat, it shuts the compressor down long enough to start cool ... Air Conditioners

I have a Ducane fits all 92 my lanlord installed,about 3 months ago.The thermostat is a new digital. The temp is set on 68,and if i go to 72 for example,the furnace starts and runs fine for about 3 to 5 minutes.The burner shuts off,the blower continues to run,And the buner tries to relight,and it fails to do so.The only way to get the furnace to run again and blow hot air is to shut the system off and restart.


Sounds like you are not proving flame to me. Could be a variety of things. I think it may be the board...but that is a guess from past history with Ducane ... Air Conditioners