I have a Rheem ac unit for a trailor. The wiring

\015 I have a Rheem ac unit for a trailor. The wiring for thermosta has been broken. How do I rewire it?\015

Answers :

Red goes to rc/rh
\015\012White to W
\015\012Green to G(fan)
\015\012Yellow to y
\015\012If a common it's usally blue or black

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Rheem Model RQNJ-A042JK Heat Pump Unit wired to a protech 520 Thermostat. Everything OK in auto mode. Fan will not run in on mode. All wiring connected except orange and black. Do not have original manuals for either unit. Installer went AOL and out of business without leaving me the manuals. Anyone have a solution. I know that Rheem is notorious for their wiring color tricks and I do not want to screw something up. Here is the wiring as it is now: Red - R Blue - B Yellow - Y White - E Jumper -


Connect the orange to the o terminal.\015\012Dave ... Air Conditioners

I have a Rheem A/C Heat Pump split with gas backup. The gas unit is mounted in the air flow directly before the A/C HP coil. Should the gas unit be wired as stage two heat, or is it OK to wire it as just aux/EM heat? There is no other heating unit. What is the difference between stage two and aux? Please note that the aux gas heat cannot come on if the heat pump is running or it may hurt the heat pump due to the gas heat units location.


Stage 2 is okay as long as there is a fossil-fuel kit accessory wired in the field control wiring. EM heat would only allow gas furnace operation if the thermostat is set for EMER HT mode.......this is not ideal and not recommended. Dual-Fuel applic ... Air Conditioners

I have a Rheem Gas Furnace with an old analog thermostat (Wires conneected to terminals R and 4 for the thermostat). I went to install a Rheem digital and programmable thermostat and it indicated that it would not work for that wire configuration (Instructions indicated that the thermostat would not work with wires to the #4 thermostat terminal). Is there a setting on the furnace circuit board I can change, or is there a digital, programmable thermostat one can use on this unit - Model RGDJ 12EA


If you have 2 wire at thermostat Terminals at furnace that the thermostat wire attach to should be R & W if your new thermostat has R & W terminals is should work, an easy thing to remember is the red wire on R the white wire on W. If 4 wire ... Air Conditioners

Rheem Model RRKA-A042JK10E, replacing the blower motor on the unit, the wiring diagram shows number instead of color of wire, now I can not figure out what color wire goes in what number on the blower


... Air Conditioners

I have a Rheem ac unit for a trailor. The wiring


Red goes to rc/rh\015\012White to W\015\012Green to G(fan)\015\012Yellow to y\015\012If a common it's usally blue or black ... Weather King 12AJA4801AH Air Conditioner

Our rheem RAHE 036JAS central air's wire (electrical? it looks like it.) that's connected from the unit (gas heat) inside the house to the unit (compressor) outside the house was cut clean. who do i call to fix it? an electrician or an hvac tech? thank you.


... Air Conditioners

I have a Rheem model RRKA-A036JK08E unit and I want to wire a new digital thermostat. Do I attach the blue wire to Y1 and white to W/B?


... Air Conditioners

I have a rheem criterion ii a/c and furnace. The power source from the a/c outside unit is not hooked up inside. Where on the unit indoors does the wire attach.


Two wires go from the inside unit to the outside unit. Y terminal and C terminal (both low voltage). Power should come from circuit breaker panel (20 or 30 amp double breaker). ... Air Conditioners

Rheem rand-024jaz ac unit not turning on. Thermostat shows power. Blower on furnace runs. Unit outside appears to have no action. Low voltage wire intact.


... Air Conditioners

I have a rheem furnace. A week or so ago, we had a burning smell, and the furnace shut down while I was gone. When I came back, it did start again, but the smell was still there. I called a guy who came over, found some melted wires (dont know if they were in his pocket or not before he came), and the unit worked for about four hours after he left...then there was a new sound..a chirping sound, and then the heater died a couple of days ago...I took the squirel cage apart, took the motor down, an


Your control board may have a problem. When the burner fires up, after a time delay of about 45 seconds, you need to use a voltmeter and see if the terminal marked H for heat has 120 volts coming off it. This voltage will be the power to spin the blo ... Air Conditioners

Need wiring diagram fro rheem 2.5 ton outdoor unit model# 13JA24A01


I need wiring digiram model 36 ... Air Conditioners

Wire diagram for air handler rheem rhsa-hm3617Ja to thermostat and outdoor unit


... Air Conditioners

I need a wiring diagram for a rheem model#RRGG-12E49JKR compact unit


... Air Conditioners

Thermostat Connection ________________________________________ I just purchased a rheem rqpm series 4ton packaged heat pump and a honeywell pro th4210d thermostat. I had 15 kwatt heat strips installed in the heatpump as I live in norther florida where the temp might drop to 20 degrees occasionally. I am unclear as to how to connect the thermostat. The wires coming from the heatpump unit are red, yellow, blue, green, white, and brown. The thermostat terminals are as such: E Aux Y G O L R B


Jumper E to Aux, OR B + O, G--green, R----red(power), & C--------common. w2---------white, Y.....Yellow and finally the Brown-----------PRCrossed my fingers too & go for it. worst is a warning hum &/or sparking one one terminal whic ... Air Conditioners

To what terminals do the two wires coming from the a/c unit connect to on the furnance?i have r w g y c on the furnance board. its a carrier tech 2000 a/c and a rheem criterion 2 furnance


The 2 wires that come from the outside unit will connect to the Y(Cooling) and the C(Common) terminals on the board. It doesn't matter which wire goes to either one, they both work either way. Have a good one! ... Air Conditioners

I have a intertherm model 9007590 AC unit. The condensing unit was changed to a unit that has a common wire and a y terminal and the old condenser unit had three wires at condensing unit. I can't get it to run and I think some of the wiring has been changed. I need to know how the low voltage wiring is suppose to be and if I need a four wire or five wire stat due to the condenser being changed. What stat do you recommend for this unit. Thank you.


The unit with3 wires was set up as a dual transformer the new unit is single transformer system. it needs to be rewired at thermostat,furnace,and ac ... Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

My dog chewed up the t-stat wiring on my outside a/c unit (compressor?). I purchased some t-stat wire at Home Depot and replaced the wiring. At the outside unit, I connected the new white wire with the brown from the unit, and the new red wire with the yellow from the unit. This part was still connected from the previous install, so I copied from how it was wired before. For the wiring to the house, this was disconnected completely by the dog, so I connected the new white wire to the white w


Hello,Yes there is a 3 amp blade fuse(same as in a car) in the blower unit,take off the door and it is plugged in to the(curcuit) board.Pull it out and slip a new one in.That will restore the control voltage.Your repair sounds correct.Some times ther ... Air Conditioners

I have a Tempstar 9000 airconditioning unit and while I was weed wacking I accidently cut a wire to the unit. I replaced the wire but now the unit wont turn on and also my furnace blower wont work even in the "on" position. I have a energy saver unit attched to the a/c unit as well. One wire connects to the a/c unit and the other to the energy saver. If I push the connector on the unit with the panel off the unit will run. Cansomeone tell me how to connect those four wires?


Hello TLOEKS You blew the transformer FUSE inside the blower unit! It should be a 5amp blade fuse like the one that goes in a car.It is located at the curcit board at the blower compartment.Replace that to restore low voltage power and every thing wi ... Air Conditioners

Need to connect 3 wires from pole to 2 wires in unit


It sounds like a 120 volt line coming in from the pole. Red is the hot wire, white the common or neutral wire, and the green ground. Hook the red and white to the two main wire lugs in the unit and the green goes to the frame or ground lug that will ... Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

Need to change a broken blower motor in RUUD central air unit. Old central air blower motor (GE electric) was connected with brown and orange wire to 15 MHD capacitor. Another orange wire from central air unit connected to orange motor wire on capacitor. Black wire from motor (Hi Speed) connected to central air unit. Blue and red wires not connected. New motor is an AO Smith FD6000A. Has Black, brown/white, brown, blue,yellow,red, white and black wires. Need to connect to a 5 MHD capacitor. M


On the motor should be a diagram detailing the wires. brown white goes to either side of the capacitor and brown wire to other side of capacitor. hi speed goes to normally open contact on the indoor fan relay and the wire designated common on the mot ... Air Conditioners

I have a Carrier HVAC unit model #38TKB62300 and the unit outside stopped working. From the exposed wires outside the unit, I noticed that when I pulled gently on some wires, it make a clicking sound. So I took off the cover and back panel and literally the wire connector, feel out of the box. I have detailed pictures of the wires that are not connected. There is a "Brown" wire and "Red" wire that are not connected, so I touched them together to find the Capacitor moving in and out. However,


There is a short either in the wiring or one of your motors ... Air Conditioners

I have a friedrich mr18y3ea outside unit and mw18y3e inside unit what size wire for the two unit i think doublepole 20 amp outside unit 12 wire do you need a sept. wire for the inside unit or it come off the outside unit


... Friedrich Air Conditioners

Condensing unit while weed eating the yard i accidently got the airconditioning unit wire wrapped around the weed eater. The unit immediately shut off. There is no visible cut or damage to the copper wire, but it did cut through the plastic surrounding the wire. Can someone please tell me what i might be able to do to try and get the unit to come back on. once again it doesnt seem to have any damage to the wire. I flipped the breaker off and back on and reset the thermostate... please help!


Probably one of the wires going to the control board or contactor has been pulled off when this happened. If you feel comfortable trying to reconnect these comment me back and I will try to walk you through it. PLEASE REMEMBER THAT THE CONDENSER HAS ... Goodman CLQ36AR49 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0731 seconds