Having problems with your Air Conditioners ?

Spt portable ac unit keeps tripping and will not turn on


Answers :

These have a tank in the bottom that can fill up in high humidity. The red LED light for the pump flashes when this happens. You need to take the black plug out from the back and drain it into something. There is a white cap that holds the black rubber plug in. The white cap is threaded on over the black rubber plug.

If it has been used for two or more seasons then you probably have some goop in the pan that causes it to not drain properly and the only way that I can get mine cleaned out is to take it apart. There is a capacitor inside that you will want to be careful around.

Hope this helps.
Sounds like you have a short in the high voltage wiring. The compressor may be bad.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Spt portable ac unit keeps tripping and will not turn on


These have a tank in the bottom that can fill up in high humidity. The red LED light for the pump flashes when this happens. You need to take the black plug out from the back and drain it into something. There is a white cap that holds the black rubb ... Sunpentown WA-1220E Portable Air Conditioner

Model # m6p09s2a portable maytag air conditoner unit...red light keeps blinking at the unit where power button is located....unit will not turn on. the light just keeps blinking


Greetings,I have the same model air conditioner, and had the same symptoms. As you've probably discovered, Fedders is the company that actually built it, and went of business. No one is supporting it any more.However, you ma ... Maytag Portable Air Conditioner M6P09S2A

When in heat mode heater keeps turning on and off has trouble to keep running cuts in and out for about one minute then only runs for short time and of sometimes trips the switch in meter box ( small green light on unit turns on not the on light the one on the other side)


The cutting in and out is indicating that it has reached its internal thermal limits .. its too hot inside .. that trips a thermal breaker .. the breaker resets when the unit cools ... the problem is almost always caused by not enough air flow ... th ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

I have a Haier HPRBO7XC7 portable air conditioner that isn't working properly. When I turn the air conditioning mode on, the cooling unit seems to turn on, but then stops after about a minute or so, and the fan just keeps running. The unit is only about a year old. I purchased it last summer, it worked fine and then when I pulled it out the other day, it had this problem. Any suggestions?


... Haier Air Conditioners

I have a Bryant AQS Model No. 594DN042-E that keeps on tripping the Two Pole 40A breaker. The unit will turn on only briefly, several seconds maximum, sometimes the breaker will trip immediately.


Capacitor is cheapest fix. ... Bryant Air Conditioners

I used my portable mastercool about 4 times last summer. Now, neither motor will turn on. It is getting power and I checked to make sure all the connections were good. I could not find a trip on the unit so I am at a loss why a practically new unit would just quit working


If not cleaned out properly at the end of the season rust and scale can make both motors quit. Try unplugging the unit and spinning the blower wheel by hand several time. Then try turning the shaft on the water pump by hand; that may free it up. ... Mastercool Portable Air Conditioner

My breaker trips when the outside unit tries to turn on. The inside furnace runs. I cut the inside unit off and the breaker doesn't trip. I manually turn on the outside unit by depressing the cont


Hello, there is a short to ground somewhere, check all the wiring from the inside un it to the outside unit and make sure nothing is touching metal. ... Goodman Air Conditioners

I have a goodman CKJ42-1B air cond. unit. It keep tripping my AC breaker although continues to blow air - just not cool air. Once I turn OFF then ON the breaker the AC works fine for about a day. Then cycle repeats itself..Help.


Try cleani ng the unit outside with your garden hose first .sounds like its kinda dirty .the dirty er the coil is the higher the amp draw is when it is running .what size is the breaker in the box .thats a 3 an a half ton condensor ... Goodman CKL36AR36 Air Conditioner

I have a KF9000E used to cool a network rack. The unit worked fine last summer. As the weather warmed up this year I turned it on and it keeps tripping the electrical breaker. Anyone have any idea as to why this is happening?


Run it on fans only and see if it runs. If it does, suspect the compressor. It may be something simple like wetness in the electrics. One component appears to have a short circuit or earth fault. If you can isolate them in turn and switch on until it ... Air Conditioners

I just purchased a souleus 12000 btu portable air conditioner. The unit works fine but keeps tripping the circuit breaker in my apartment. What causes this and can it be fixed or is it just the wiring in the house?


First, you need to determine what, besides the Souleus, is on that electrical circuit, and whether the circuit is 15 or 20 amp.12,000 BTU A/C's tend to pull 10-12 amps, and they can peak just under 15 when the compressor starts. So a new, ... GE APN08AA Portable Air Conditioner

My GE Portable AC will only turn on intermittently. Water bucket is empty. Filter and coil are clean. Circut breaker has not tripped. I think the power button is broken. This unit is in pristine condition and has been used very little, it looks new. What do you think the problem is?


Have you recently moved the location of the AC? Is it connected to the power point as per the instructions given in the ... GE APN10AA Portable Air Conditioner

The circuit on the plug keeps tripping when I turn the unit on. Goldstar wg6007


Most AC`s have a start capacitor at the compressor pump, if this start capacitor is defective your compressor will not start and cause it to draw more current than is normal, when you turn the unit on listen, if you notice a humming sound like an ac ... Goldstar WG6007R 6 000 BTU Window Air Conditioner

Turning on the unit trips the GCI on the plug. Unit beeps and warning alert flashes and shuts off.


... Air Conditioners

Sharp AF-R1108X Thru-Wall/Window Air Conditioner was working fine all summer. The past 2 days were extremely hot out. the unit was working around the clock. the unit was in low cool and keeping up fine. Then it started making beeping noises and going into energy saving mode and cycling the unit on and off constantly and would not allow me to turn it off by using the selector button. I had to unplug the unit to turn it off. I left it off for about ten min. hoping it would reset it self. I turned


... Sharp AF-R1108X Air Conditioner

I have an ACE184XRO window unit. The reset button keeps tripping everytime the unit has reached it's cooling temp. It' used on the power saver control. How can I keep it from tripping the button?


... Whirlpool Window Air Conditioner

Outside inverter unit keeps running hours after the ac unit has been turn off - Try shuting down the mains supply but it keeps running after the switch is turned on.


Did the indoor unit ice up also?sounds like the compressor contactor/relay has become welded&stuck.change contactor. ... Panasonic Air Conditioners

Hello, my heat pump is a 4 ton unit, it heats ok but it keeps tripping one of the breakers, the 40 amp cooling breaker. I have put a new thermostate, it keeps running after the breaker is tripped and the outside unit is off. I am thinking the breaker could be bad the other two breaker are 60 amp. do all three need to be 60 amp. Thanks


Hello Jack, \015\012\015\012Let me see if I have this right. Your heat pump keeps triping the breaker that is going to your airhandler. The Heatpump is on its on breaker and can not trip the breaker on your air-handler. However, the 40 am ... Ruud UBHC Air Conditioner

I work in a hotel and our lobby a/c keeps tripping off I have to continuously keep back and forth turning it on and most of the time it wont even turn on just clicks back off, or stays on for a couple of minutes and trips or not even at all not even the fan, then sometimes it will stay on for a couple of hours is this normal? My boss says thats just the way it is. But the 3 yrs i've worked here I dont remember it doing this just maybe this year.


The unit is either too small to cool the area or the compressor is going out. Replace the unit, cheaper to buy a new one than to fix an old unit. ... Air Conditioners

A6414w7b b wall unit gfi plug keep tripping problem: fedders wall unit brand new keep tripping the gfi on its power cord


GFI plugs go bad very often if you had a storm in you area. You need to replace the plug. Go to aplliance parts house and they will sell you the new cord. Feed back please. ... Fedders A6D24E7D Wall/Window Air Conditioner

My indoor unit on my heat pump will not shut off. The electric heat keeps running, and the fan keeps running. It only happens when it is really cold, like 25deg or below, above that and it functions fine. The outdoor unit shuts off, but the indoor stays running. I do HVAC work, but I have never seen a problem like this. I have switched the stat out, and its just so strange. I figured the relay may be stuck, but if I turn the stat off, it turns off shortly after which tells me it may not be the c


I would venture to say your stack relay is getting stuck. either that or you have a short in your low voltage wiring somewhere that is not always making contact....or it may be making contact through another median...like ice or frost. Remember ele ... Intertherm P3RA-036K Air Conditioner

Ac unit reset keeps tripping


If it runs in test mode but not during normal, there is a wiring issue. ... Whirlpool Air Conditioners

Hello, I have a Fujitronic FA1300 portable AC unit that has been malfunctioning. What happens is, when I turn the unit on, it runs for a few seconds, and then stops working. When this happens it beeps several times, and the green image on the right side of the display panel begins flashing. The image looks like a square with the top side missing, and four dots inside the box. The unit will not turn on until I hit the reset button located on the side of the plug. The problem repeats if I turn it


This is the main control board in the AC unit malfunctioning. It thinks either the unit has been opened, or switched mode, which obviously it has not. If you have tried resetting it multiple times to no avail then it unfortunately needs a replaceme ... Fujitronic FA-1300 Air Conditioner

My AC unit is not blowing cold. I have two. One small and one big . I just noticed that My upstairs was not cooling off. So I turned both units on and went out sid to check them. The small one is running fine fan blowing cold freon running through. The big was not running at all. I sprayed them off and while doing that the fan on the big unit began to turn. Now it is running but every now and then it keep making a noise like a motor is trying to turn on. and the freon line is not as cold as the


The start capacitor is in question and the fan appears to be overheating, That is where the water camre into it. You may need a HVAC tech to make your repairs. Good Luck _Ned_ ... Air Conditioners

Mit.hp model MUH24WN Unit was working fine shut off at night went to turn on during day and would not come on it was tripping the circuit (replaced circuit) still tripping we know it is definately compressor unit but I don't believe it is grounded tech. telling me we need a new unit other sources that work on these units say something may have gotten into the compressor, If you could tell me the possible answer to this problem?


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I turn on the unit and in about 1 .5 min it trips the cb ,, I put a amp probe on the circuit and found out that after 1.5 the unit jumps up to 40 amps on a 15 amp breacker which the unit is rated for . the unit never actually runs ,, it just trips the cb


Firstly was the unit working previously on the same circuit? , if yes most likely there is a problem with the compressor(pot)this can be the compressor seized or winding shorted, It can also be the Capacitor for compressor faulty, It is worth replaci ... Fujitsu 18C1 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy