Blower fan runs at one speed - very low

\015 I just had a Amcoraire UCHW-H12AF2 uni installed and everything seems to work OK but the inside unit blower motor. It runs at one speed only and that is very slow. I had the contractor recheck the wiring and that all looks good. Can you help with this problem?\015

Answers :

Replace the controls thank you for useing fixya please rate me
Its the motor control unit faulty.that unit is located on the board that has to check.as from where the motor gets current/votlage.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Blower fan runs at one speed - very low


Replace the controls thank you for useing fixya please rate me ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

Blower fan runs at one speed - very low


There is a sensor on the indoor coil that needs to reach a certain temp before the fan speed will increase. Sounds like the unit is undercharged if the sensor isn't reaching the temp it needs to. ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I have an LG model LP150HED and the blower fan will only run on low speed even if high speed is selected on control panel.


... LG Air Conditioners

Goodman heatpump the heat comes on but only the low speed of the blower fan will blow and it cuts off after it runs for about and it cycles the same again after but never on high speed


I think your run capacitor for the blower motor needs replacing. \015\012If it goes out the motor will not develop full speed and will shut off on it's internal thermal protector. When it cools off it will kick back in until it gets hot and shu ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Bonnair, pyrox, gemini 1 wall gas heater fan stopped running, checked wires into fan box, 4 wires,1 common, next one down low ohms to common, 3rd one down open circuit bottom one is earth. Should there be two wires into motor with low Ohm readings instead of one open circuit ?? Thanks Russell


... Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

I. The outdoor heat-exchanger fan runs at a low speed (with a humming noise), when the home temperature is below the set-point. ii. When home temp. in high, fan runs at full speed, like normal. iii. When A/C breaker is shutoff (in main switchboard), the fan stops. Need help diagnose the problem.


It could also be the contactor; basically an electrically-controlled switch that in turn controls the compressor and the condenser fan. If it's a 220 volt motor, and one side of the contactor has very high resistance, it'll be seeing 110 volts inste ... Air Conditioners

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

MY GOODMAN CPKJ24-1A UNIT WENT DOWN.TOOK FAN OUT SAW WIRES SHORTED OUT AND MELTED COMING OUT OF FAN MOTOR I REPLACED THE FAN MOTOR .THEN REPLACED DUAL RUN CAPACITOR THEN THE SWITHING CONTROL. TRIED TO START UNIT FAN RUNS AT A VERY VERY LOW SPEED AND SORT OF WISTLES WHEN RUNNING ALSO UNIT IS NOT KICKING OVER EVEN HAD CAPACITOR CHECKED WHY WONT MY AC UNIT COME ON


... Goodman Air Conditioners

I have got vulcan evaporative cooling system and the fan has stopped working. It blows air but at very low speed. i checked the unit and can see the fan moving at very low speed. The water pump if working fine though. can any one help. Thanks


Try lubricating the fan brings ... Air Conditioners

I have a rheem electric furnace with 2 speed fan, seems like the fan runs full bore when its on, even when i just cycle the blower control to ''on'' and its supposed to run at reduced speed. I have to experience with central heating and air, was wondering if it would be the circuit card with the dip switches. Unit was installed in 2003 with a heat pump.


If it is a variable speed blower most likely the dip switch settings. Check the installation manual to see how to slow it down. ... Air Conditioners

After a power outage and surge, I tried to run the carrier high efficiency furnace "FAN" only to circulate air in the warm house. when I stated the blower, it ran on slower spped than normally.usually cycles between high and balst furnace high....now its running slow.I tried the heat cycle and the blower speeded up a minor amount over just with the fan circulating....is there an internal circuit breaker that could've beed bitten with the surge??


Try replacing the fan capacitor some time power surges zap them.its usually a 5uf or 10uf @ 370vac if you change it and runs fine it was the capacitor if not blower fans keeps slow verify that full voltage is getting to it ex 230 volts or ... Air Conditioners

My fan only runs on high. No low or medium speeds. The remote shows low, med and high changes but the fan only runs at high.


Check with another same type remote. If same problem, Check PCB. If all speed wires plugged properly? If yes, problem with PCB.Replace it.Thanks, helpful? ... Hampton Bay Air Conditioners

Self contained a/c unit i put new blower motor in it about a year ago and never used it ! but i lost the paper work on what wire is for max speed. red is the low min, for furnace. it has black blue white and red wires and it is a multi speed blower. SO wich WIRE WOULD BE THE HIGH SPEED ONE


THERE SHOULD BE A SCHAMATIC ON THE SIDE OF THE FAN MOTOR WITH THIS INFO ... Air Conditioners

I have a 1993 yellowstone camper with a coleman wall thermostat. on the bottom of it- it has a heat/cool switch on one side and the other side has a low-high-fan switch. when we run it on low or high it gets cool but the fan never shuts off.if we put it on fan it shuts off with the compressor but it doesn't blow cool air. any advise?


Thank you so very much for your answer! I'm glad I came to this website before I began a new project. I was about to re-wire my unit based on my ex-husbands advice!!!! ... Coleman Air Conditioners

When I press the button to change the speed of the fan it does nothing, and continues to blow at one speed and it is just about equivalent to the speed of the slow option...any ideas why? Also it will run for about 10 minutes and then stop blowing out cold air and it is just the fan blowing.Everstar portable air conditioner,model MPK-10CR


Is it new? There may something wrong with the electronic circuit board not allowing other fan speeds. Try unplugging it for a while and try again. There is a temp sensing bulb somewhere on unit most likely on front where hot/warm air from space enter ... Air Conditioners

1996 Coleman Model 7333C8876. Have 2 units on our Motor Home one day it was hot so I had both units running controlled by a Electronic Climate Control system. It got cool in the evening so I turned them off. The next day when i fired them both up on high the rear was fine. But the front will only cool on Low. The fan will not run on high and you can hear a slight noise coming from the unit. But the fan will not run on high.


Check to make sure the drain tube is clear. It sounds like the blower fan is dragging in water buil-up. ... Air Conditioners

I HAVE A GOODMAN PACKAGED AIR CONDITIONER M/N PCO30-1 B REV. E C/W 9.8 K.W. ELECTRIC HEATER INSTALLED IN A MOBILE HOME. WHAT WOULD YOU RECOMMEND FOR A BLOWER FAN SPEED? CURRENTLY IT IS SET ON HIGH SPEED , HEATER AMPERAGE IS CORRECT, BUT THE DELTA T IS TOO LOW. MY CONCERN IS , SLOWING THE BLOWER SPEED FOR BETTER HEATING MAY BE TOO SLOW FOR COOLING. tHANK YOU.


Hi,\012Many have sepaarate speeds for heating and cooling....check it out there should be a heat relay and a cool relay and the motor taps are hooked to each so maybe you can just do a bit of switching wires.....\012\012But, really ... Goodman Air Conditioners

Small orange wire from switch to capasitor burnt to red wire to compressor now outside fan won't run, can move brown wire from green terminal to orange wire terminal on cap and fan runs low speed


You need to replace the cap, there is no low speed, the capacitor is bad ... Ruud Central System Air Conditioner

I have a bonaire VSL75 evap. Fan only working on low speed, on all speed setting except for boost (then fan runs at boost).Has a climate technologies touch pad control.


... Air Conditioners

I have a Rheem Criterion Gas Furnace. Mod #rcba-24576617 s/n mo494 Even if the a/c or heat is off position and the fan is on auto. The blower fan motor consent run. I must turn the main power off to turn blower off. Is it because the mother board is bad. And if so, could I order one thru your company?


Actually this sounds like a thermostat or relay malfunction. \015\012\015\012As for parts, you have posted this question on Fixya, I am sorry but Fixya just answers questions and does not sell any parts. ... Air Conditioners

I have a hampton Langston 60" ceiling fan - my pull switch broke and I am trying to find a replacement part - Tried Westinghouse 77020 and 77021, I still don't have all 3 speeds The 77020 - had High and Low and did not stop The 77021 - has High and Low and does stop I am looking for one that will have all 3 speeds and also stop The inscription on the switch states E98635, 3A 250VAC, 6A 125VAC and the two replacements that I purchased at Home Depot (77020/77021) both had the same insc


... Air Conditioners

Carrier 58RAV095-16 will process thru the test sequence properly: inducer fan, ignitor, blower high, blower low, all ok. fuse checked good on controller board. when commanded to supply heat by the thermostat controller in the living space the unit runs with fan only, no gas, no ignition. changed thermostat controller, no joy.


Hello \015\012Your closing the circut,and getting power to the ignitor.\015\012\015\012Have you tried another t stat or check your wiring low voltage side.\015\012\015\012Is there a pre purge fan for gas to be cleaned ou ... Air Conditioners

Carrier 58RAV095-16 will process thru the test sequence properly: inducer fan, ignitor, blower high, blower low, all ok. fuse checked good on controller board. when commanded to supply heat by the thermostat controller in the living space the unit runs with fan only, no gas, no ignition. changed thermostat controller, no joy. Comments: Jan 31, 2010 - thermocouple/ignitor is ok and positioned well. It tests ok too. I changed it last year. I am not getting gas flow so I suspect gas control va


Go to the furnace and turn off the power take the door off you must have a multimeter inhand with the cover off the furnace and access to the gas valve put yor meter leads on the wires going to the gas valve turn the power on and after the ignitor gl ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0998 seconds