Having problems with your Air Conditioners ?

My MSH 024 Air Conditioner keeps tripping off at the mains switch

\015 When switched back on at the mains it goes for a minute then stops again. The unit is in a shop 25square metres and runs at 21'c. Ive tried switching everything else off (ie before openning), but the same thing happens. Ive had the unit 4 years, without any problems, it just started a couple of days ago. My clients and staff are complaining. Can you help\015

Answers :

FIRST TRY TO CHECK THE CIRCUIT BREAK THAT IS CONNECT TO THAT AIR CONDITION, USUALLY IS A 30 AMPS OR 40 AMPS CAPACITY, MAYBE IS BELOW THE AIR CONDITION CAPACITY AND OVERHEAT THE BREAK, OTHER WISE UR SHOULD CALL A TECHNICIAN TO CHECK THE COMPRESSOR AND THE COIL OF THE CONTACTOR

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My MSH 024 Air Conditioner keeps tripping off at the mains switch


FIRST TRY TO CHECK THE CIRCUIT BREAK THAT IS CONNECT TO THAT AIR CONDITION, USUALLY IS A 30 AMPS OR 40 AMPS CAPACITY, MAYBE IS BELOW THE AIR CONDITION CAPACITY AND OVERHEAT THE BREAK, OTHER WISE UR SHOULD CALL A TECHNICIAN TO CHECK THE COMPRESSOR AND ... Comfort-Aire MSH-024 Air Conditioner

My air conditioner Daewoo DWC-100R keeps tripping the switch on power bar ... I just purchased it second hand and was assured it was in perfect working order. I am 65 yrs. old female with no knowledge of air conditioners and a limited money situation. We are in the ;middle of a heat wave and my apartment gets very hot. Can you help me?


Have you tried to plug it directly into the wall Maybe the the power strip you are using is not able to handle the amps needed to run air cond. If thats not it you have a short to ground that needs to be checked out. ... Daewoo DWC-100R Air Conditioner

Reverse cycle window wall air conditioner. I turn the power on and it is OK when I turn the air conditioner on either manually or with the remote it turns off and trips the main switch. I have tried the trouble shooting in the manual.


Tripping the circuit breaker means that something is shorted out. A fan motor or the compressor, most likely. Disconnect the compressor or turn the thermostat up so high the compressor doesn't start. If the breaker still trips, the fan motor or it ... Electrolux Air Conditioners

Rool out switch keeping tripping - Air Conditioners


Assume you mean roll-out switch on a furnace....it is a temperature sensitive safety control intended to limit the temperature in the vestabule or burner area. if it keeps tripping, it's because something is causing the temp to get too high. a dirty ... Air Conditioners

Window air conditioner keeps switching to fan mode. Which means on hot days it is blowing warm air. It sporadically switches to air conditioner mode. Room is hot because the cool air only blows for about 10 minutes. Help!


... Air Conditioners

Air conditioner Model MSH-RV18 when using the remote to switch on and select heat the air conditioner expels cool air not hot air. But when I select the emergency heat button, the air conditioner expels hot air Many Thanks Julie


Hello,Please, change the battery of the remote, if the problem continue, there is a reset button on your remote, reset the remote.If the problem continues, then, your remote sensor receiver on the ac unit is bad, you \015\012 ... Mitsubishi Air Conditioners

Trip switch on air conditioner


This switch may be in the attic. i had similiar problem with my a/c and thats where the serviceman said my switch was. ... Carrier Air Conditioners

I have a Goodman CKL 49-1 air conditioner. It keeps tripping the circuit breaker in my fuse panel. Any idea as to why it started doing it, could it be a bad breaker in the fuse panel or a fuse somewhere located in the air conditioner.


Usually its a bad motor, compressor or even contactor like a dead short your breaker trips to tell you there is a problem ... Goodman CKL49AR49 Air Conditioner

Air conditioner my air conditioner is saying c6 and the fan outside is not working and when you turn the power off at the main switch it works for awhile


Remote control units have diagnostic program in thecontrol, after 3 to 5 minutes of operating if the diagnostictools detect abnormal operation, then its shutdown the unit ... LG LSC121PMA Split System Air Conditioner

My Fujitsu Air-conditioner outdoor unit (condensor) now trips and cuts off its power everytime the compressor starts to engage when the air-conditioner is just switched on. What is the reason and the remedy for this problem? Please advise at your earliest convenience. Many thanks in advance.


... Air Conditioners

My air conditioner trips the main breaker - Air Conditioners


Hi, I don't know if you have a central system, window unit or what, but when this happens you have a dead short in one of the parts, more then likely a locked up compressor. If you do not know about electrical motors and so on, I wouldn't want you to ... Air Conditioners

I've changed out my central heat and air ,with a larger unit , after 5 weeks working fine ,now if my air conditioner ,hot water tank and stove is on along with a few minor appliances my main breaker trips , my main breaker is 150 amps the max for my box , i've heard that you can wire directly to a power meter through a breaker


No,you can not wire directly to a meter. All wiring must come through the circuit panel or sub panel.150 amps is sufficient to run what you describe. You may have a weak main breaker or loose wiring to these appliances. Place a amp meter on a i ... Goodman Air Conditioners

I have a tempstar combine air conditioner and furnace. the furnace will run fine then the manual limit switch trips. i can reset the limit switch and it will operate a couple of cycles then trip again, any idea.s


If the unit is around 6 years old then it could be the combustion air motor. If the unit is older then you need to inspect the heat exchanger for signs of cracks. Take the top off the unit to inspect. Check to see if the metal around the reset is ... Air Conditioners

Air conditioner keeps tripping the circut breaker


... Air Conditioners

Admrial air conditioner keeps tripping it's plug


Hi, you either have a short in a componant or it may be that the outdoor coil is dirty and will need to be washed out with your garden hose. If it trips but you are able to reset it and it will run for awhile, its a good sign the condenser coil may b ... Air Conditioners

The main breaker keeps tripping when ac starts up . after we trip it .it works again.we put a new breaker switch on . still trips


Is your house running off 100 amps or 200 ? ... Weather King 10AJA6001AH Air Conditioner

RV Air Conditioner Keeps Tripping Circuit Breaker & Compressor


It sounds like the unit was miswired at the factory, since when the A/C is "off" at the thermostat, there should be no calls for cooling or for the fan to run.\015\012\015\012You also stated the most puzzling issue, with the breaker turne ... Dometic Rooftop RV Air Conditioner

Dometic Duo-Therm air conditioner: keeps tripping the breaker. Unit is 4 years old. 57915-331 Everytime we use it; it cools the camper just fine but out of the blue it trips the breaker and won't work. Sometimes it cycles off and on, off and on. This unit is in a travel trailer, with a ducted system. suggestions ?


First clean the condensor with air blower or water pump and clean the filters.If the same problem persists there is a choke up in the refrigeration piping, cut from the discharge side and suction side flush the system with nitrogen, replace the filte ... Dometic Rooftop RV Air Conditioner

Carrier air conditioning not working. Just making a humming noise. went to basement to try and reset fuse. Fuse keeps tripping off and air conditioner will not kick on.


... Air Conditioners

I have an outdoor Amana model# RCE42C2A air conditioner compressor unit. The pressure switch located on smaller tube (not sure if low side or high side) keeps needing to be reset, not sure if switch is the problem. Any suggestions?


... Amana Air Conditioners

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

I have an LG Air Conditioner (model LST243H-2). The circuit switch (in the fuse box unit) keeps switching over to off. My apologies that I'm not technical in my explanation!


Please do not activate again.Call repairman. The circuit switch trips due to:1. Compressor hing amps. 2.Any short circuit.3.Compressor grounded.By resetting the breaker without rectifying the fault will make major expenditure ... Air Conditioners

The main power supply was cut off but after it was back,my Fuji air conditioner RSW9CB can't be switch on. The red 'Öperation' light blinks twice(continously) and the green ' Timer' light blinks continously. Main connections and the remote controller are all in good working condition. My guess,it could be from the malfunction from one of the sensors. Pls help me. MSF Tq


Check input connection in indoor unit, may be loose contacts. And also your room thermostat sensor may be defective. ... Air Conditioners

My Mitsubishi msh26sv keeps tripping the main switch booth green lights come on when you turn it on and it runs for about 2 min then trips


... Mitsubishi Air Conditioners

A detailed question is important to get you a relevant answers