Having problems with your Air Conditioners ?

Airco Indoor unit SC 12 ZKG Samsung After a while, 2 seconds to several hours the unit switch off. Lights on the unit green and yellow blink for several seconds. The switch off time is increasing shorter. Started with several hours now a days it only last a few seconds to switch off. In this country (Mozambique) is not sufficient kwowlegde to repair the unit. It was working for about 4 years. What can be wrong? Beste regards, Cees van Perlo - Electronic engineer [email protected]


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Airco Indoor unit SC 12 ZKG Samsung After a while, 2 seconds to several hours the unit switch off. Lights on the unit green and yellow blink for several seconds. The switch off time is increasing shorter. Started with several hours now a days it only last a few seconds to switch off. In this country (Mozambique) is not sufficient kwowlegde to repair the unit. It was working for about 4 years. What can be wrong? Beste regards, Cees van Perlo - Electronic engineer [email protected]


... Samsung Air Conditioners

Unit is a Samsung AS09A1VE Air conditioner Split System Unit turns on with remote, green light comes on with start bells. Another bell sounds yellow light comes on, unit switches off green and yellow lights start flashing, all in around 5 to 10 seconds, unit will turn off with remote, lights go out. I reset the unit by disconnecting power and reconnecting. Unit worked fine for several hours after that (although it did discharge some some small black debris. It then repeated the same proble


Hi,\015\012This sounds like a problem with it either being too cold outside or the unit is low in charge. What happens then is that the indoor coil getts too cold and the unit will shut down before is freezes over.\015\012The cold outside ... Air Conditioners

This is about a 15 YEAR OLD Trane XE1000 30,000 BTU A/C unit. The A/C was not working, but right after I called to have someone come fix it, it started working again all by itself. When the unit was not working (for about 18 hours). The house got up to about 80 degrees with the thermostat set on 70. When the HVAC tech got here (next day), he told me the compressor is shot because the thermal limit switch inside the compressor is overheating. The area where the thermal switch is getting warm, but


You can wait just buy a capaciter start system theat will override the old start capaciter, this is a common problem for all ac systems. just bu the ac start replacement and yo should be good to go for a couple more years. and if you want a reference ... Air Conditioners

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

I've just moved into a home with an existing Armstrong Concept 10 A/C unit that's at least 15 years old. When I left for a 2-week vacation, the unit was working great. I set the thermostat to 77 to save energy. Upon returning, I lowered the thermostat to 70 and waited, and waited and waited several hours only to find the temp. in the house was not lowering, it was actually rising! I could see the unit's fan blade was not moving so I checked the circuit box in the basement, and the A/C breaker


Hello 93 The compressor caused the breaker to trip.A weak capasitor or burnt wire is a common cause.It sounds like the compressor is NOT on even though the fan is.It may need a new wire or maybe a HARD START kit to help restore operation.Call for hel ... Air Conditioners

No A/C My unit will power on and the fan works, however when I turn it to the Cool mode I can hear a click in the unit, the cool light comes on for 5 seconds or less, then it will click again and the light will flash 9 times. The warranty on the unit is 4 years however only covers parts, labor is $90 per hour......Is it just a fuseable link/circuit breaker?


It seems that that the overload of compressor is tripping on and off, either your compressor overload is defective or the compressor itself ... Danby DPAC8399 Air Conditioner

I have a window air conditioner. When it runs for several hours it will trip the breaker. I have had the unit for 5 years. I bought it used and even though it has always shaken when the air compressor comes on it has cooled fine. Recently, however, my landlord changed the circuit breaker (had an electrician come out to do this and supposedly everything is working find). However when I pluuged the unit back into the plug for this circuit, the unit would not even operate for 10 mintues withou


It's probably fine even though it jiggles and makes noise. I would ask the landlord to change the circuit breaker again and ask the electrician what the amps were for the breaker he took out and the one he put in. \015\012\015\012Hopefull ... Whirlpool Air Conditioners

A/C outside unit will not run. Inside works, breakers are on and did not trip. No noise coming from outside unit, except for low buz when 1st turned on. After 10 seconds, nothing. Goodman # CPLJ36 - 1B. No idea how old. Have tried turning breaker switches off and on. Has been 24 hours, just tried again . . . nothing happens but that short buzzing sound, a low beep, and then silence.


Sounds like your contactor/relay on compressor defective, by the way it sounds the buzz is from the magnetic coil on the contactor but its not pulling the contacts in to start the compressor ... Air Conditioners

Have a Haier HWR05XCB air conditioner window unit that has been sitting in the garage for a few years. I cleaned it up for use in a room and plugged it in and nothing but Zeros on the digital display (00) only for about 1 second, then absolutely nothing, power button does not work. It does this every time I plug it in, I have tried several different outlets. No evidence of anything burned up or otherwise wrong from visual inspection. Is there a reset button somewhere on this unit?


... Haier Preference Plus HWR06XCA Air Conditioner

We have a residential Lochinvar Solution Boiler (model RBN090). Around 7 years old. For past 2 weeks pilot light keeps going out. 2 repairmen have come out. We have replaced the Gas regulator, the roll out switch, the thermocouple, and the pilot flame on the thermocouple. Pilot light continues to go out. No one has anwser. Pilot flame goes out sometimes when system is cold, other times after working for several hours and hot. Very random. But we have to relight serveral times per day a


... Air Conditioners

We purchased a Newair ACP-1000H for a renovated attic space. It worked okay for a while, but after about a month or two of use it started making a very loud rumbling noise, not cooling, and tripping the breaker. We couldn't get it to run for more than an hour before tripping the breaker. We have had the unit for over a year and can't remember which online site we purchased it from. How much do you think it will be to repair? or is this just a piece of junk?


It sounds as if you need to clean the coils and make sure both fans are running do you clean the filter regular if you cant do this yourself it would be around 100.00 if you take it somewhere or have someone come out ... Air Conditioners

The unit powers up and the fan blows well. The green light above the cool icon doesn't light up. Every 45-60 seconds the unit seems to strain and the fan decreases it strength for about 3-4 seconds and then it returns to blowing as bed ore. The unit does not seem to be cooling well. The unit is about 4-5 years old with less than 100 hours of use. It gets used maybe once a year. It was recently used last week, cooled great for two days and then began to function as described. Suggestions?


... Amcor ALTL-12000E Portable Air Conditioner

Own Heir Outdoor unit (HC60A1VAR) condensing unit (central Air Conditioning Unit).ESTIMATED AGE IS 3+ YEARS. Local repair service says the condensor is cracked and leaking and non repairable. He(local repair man) just looked through the opening in the air slat vents to determine that- and he/I observed a medium amount of oil that had dripped from the bottom of the unit onto the concrete base holding the unit.Has not been producing cooling for about 24 hours only.He unpluged the cooling. He advis


Yes, as well explained, he is 100% right on the money.\015\012With a device of this age, I would expect it is way beyond repair and no doubt, not "Legal" with emissions etc. \015\012\015\012In my professional opinion you should cut your losses ... Haier Air Conditioners

Several years ago I purchased 2 Split-Type Room Air Conditioners--Models RSW-17 (Indoor Unit)/ROW-17 (Outdoor Unit) and RSW-12S (Indoor Unit)/ROW-12S (Outdoor Unit). The airconditioners themselves are fine, however,the Remote Controls for both these units, Model AR-DJ15, have gone bad and may not be repairable. How/where can I purchase replacement remote units? Alternatively, where/how can I send my remote units for repair? Chester D. Copemann [email protected] or [email protected]


Type in the mfg. name in the search bar and see if you can find resources. ... Air Conditioners

Still working on our ac inside unit Coleman EB20B outside unit Goodman CKL49-1. We had a short in the thermostat wiring that we repaired. Now the AC is working when the fan switch is on run. It doesn't run with the therm switch on the cool cycle. Have we crossed wires somewhere or is our thermostat bad? Thanks Ken Rohm


You could have either situation. You could also have a bad thermostat sensor, as it talks about in this blog:\015\012http://hubpa ... Coleman Air Conditioners

We had a brand new unit put in a couple of years back. When it was installed it worked. Once winter came, it obviously was turned off. Then the following summer, it would turn on but just blow air, would not cool at all- so the unit installers came out and repaired it. It worked through the summer, then the following summer-it wouldnt cool again-they came back out and fixed it again. Third summer in a row-it is not working again!! A friend told me this morning, on new units there is a


Yes but you should have to keep resteting it you might have a major problem are you beiing charge for freon if so you have a bad condensor unit (it have a leak ) check your bill if the same thing happens again go see what the techs are doing ... Honeywell Air Conditioners

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of technicians to repair it and still not working. One fixed the switch pressure & the other the flame sensor connection. We have been advised that we may need a new unit or repair the board. As we have an illness in the family, we would like to know whether we need to purchase a new unit as p


\015\012We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component ... Air Conditioners

Twice in the last year, I have had a gas smell come from my Goodman furnace. In this last case, the smell of gas came through the duct work. There was not smell in or around the furnac itself. Some how it got into the duct work very quickly., Had tech check the unit and cannot find a leak. Everything (sensors, safety switches, etc) seems to work. Once you remove the gas then the unit seems to work fine.


Did the tech check to see that the heat exchanger does not have a hole of a crack in it...I have seen this and it is more common than you think....Make sure you get to the bottom of this as there is the danger of carbon monoxide poisoning...I would ... Goodman Air Conditioners

I have a Coleman Evcon gas furnace model# DGAT095ADA last year I replaced the T-O-D #60T82 - 313675 fan switch and works fine. This year the unit started fine, but slowly started taking longer & longer to heat up, then finally not heating up enough to trip fan switch. Manually tripping fan switch resulted in some warm air through system, but not enough to heat a house. Gas comes on and is blue what would be my next course of action ?


... Air Conditioners

I don't know what model my fan is, but it's only 3 years old and suddenly two days ago the light and fan quit working. We replaced the light switch on the wall-nothing. Took apart whatwe could of the fan to look at the wiring-all intact. We then replaced the battery in the remote and it instantly worked fine again. After putting it all back together it stayed lit with the fan working for about two hours at which time I turned it off using the wall switch. I immediately tried turning it back on a


That may be, because you were using the Remote Control to operate it, but then turned off the wall switch instead of turning it off using the Remote Control.Turn the wall switch back On and try to get the Remote Control to take back over ... Hampton Bay Air Conditioners

I have a 2000 (year) 30' Four Winds Hurricane Class A Motorhome and the airconditioning is not working in the front or back unit. I took it to an RV repair shop and they said they can re-charge the driver's unit, but can't re-charge the back unit in the living quarters, due to it being a model with a different freon set up. They said I would have to purchase a new model at $2000. What's the deal? Can it be re-charged? The motorhome is only 10 years old.


If someone replaced the rear unit with an a/c older than 1995 it is a possibility but I think they are feeding you some bull.Are you in Indiana?I found a link to Four Winds home website which is in Indiana.I would call them to find out.If you are in ... Air Conditioners

Hello. My General airco (in Cyprus) works 10% normaly. 90% it start and stops after 10 seconds the it gives low air. But sometimes, today the first time, it works normaly, but when I switch it of and start after some hours again 10 seconds cold air. 10 seconds of. Remote control: Cool Fan control High Thermostat 16.


Hello\015\012\015\012If it was a general AC it must be running on a vapor - compression cycle, it must be the refrigerant (freon) that might have leaked and ran low causing the compressor to pump less refrigerant and is working on a low p ... General Air Conditioners

I have a CGL300TQ ventless propane heater. The thermstat quit working. I have shocked the thermostat bulb several times but it still does not work. The parts list shows part# slt545 or could be slt545 thermostat control vavle which I assume is the problem. I have called charmglow several times but I am told I cannot get this part. I do not understand why I cannot get this part to repair this unit. Can you help me. Thank You,


... Air Conditioners

Fan Hello, my ac unit blower on the inside is working fine but, the outside fan isn't. i just bought a new relay switch due to that what it was a few years back. but, it's not working the outside fan. so, my question could it be another relay switch? or the compressor? Thanks


Hi wild 36.\015\012I think the problem may be a bad run capacitor. If the outside unit is humming with no action, that may be it.\015\012\015\012This could also cause the outside unit circuit breaker to trip.\015\012\015 ... Air Conditioners

No A/C. My condensing unit is running. The tstats work but no air flow. The unit is 3 years old - never had a problem. It was working up until yesterday. The filters are new. Is there a breaker-type switch at the furnace in the attic that may have tripped?


It maybe the blower motor. Determine if the blower motor is getting ac, if not getting ac to the blower motor then there might be a breaker, which would probably be located somewere near the motor, or the motor has an internal breaker or fuse. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific